Ixia Software Release Notes
IxANVL 9.27
August 2020
IxANVL 9.27 release includes enhancement to existing test suites and Bug fixes since the previous release.
The following is a brief description of Enhanced Test Suites in Traditional Networking/Non-Automotive-Ethernet Segment:
1. BGP4 SR-TE - A new test suite is added in 'Segment Routing Test Suites' family covering 'BGP SR-TE Policy'. The test suite covers 34 test cases from draft-ietf-idr-segment-routing-te-policy-08
2. ISIS SRv6 - A new test suite is added in 'Segment Routing Test Suites' family covering 'ISIS SRv6'. The test suite covers 38 test cases from draft-ietf-lsr-isis-srv6-extensions-08
The following is a brief description of Enhanced Test Suites in Automotive-Ethernet Segment:
1. SOMEIP-ETS Test Suite is enhanced with 28 new test cases.
Application Compatibility
NOTE: When you are using one or more of the applications below on a single chassis
configuration, please use the correct application versions so they align to a common
version of IxOS.
Application |
IxOS 9.00 |
IxANVL |
9.27 |
IxNetwork |
9.00 |
IxLoad |
9.00 |
VNIC |
4.00 |
Licensing |
5.10 |
For additional product compatibility information please refer to the following
online utility. An Ixia website account is required before accessing.
http://www.ixiacom.com/support-overview/product-support/product-compatibility-matrix
IxANVL Workstation Requirements
CPU: 64-bit Processors
RAM: 2GB or more
Disk: 4GB free or more
Windows OS: Windows 7 Professional 64-bit
Windows 2008 Server R2 standard 64-bit, SP1
Windows 2012 Server R2 standard 64-bit
Windows 10 Enterprise 64-bit
Windows Server 2016
NOTE: IxANVL supports the US English versions of the Windows OS. Although,
IxANVL may run on other versions of Windows OS, they are not
officially supported by Ixia. If you attempt to install or run
IxANVL on any version of Windows OS other than the U.S. English
versions, the IxANVL installation or operation may fail.
Linux OS: CentOS 7.5 (CentOS Linux release 7.5.1804, Kernel 3.10.0-862.el7.x86_64 #1 SMP)
Important Note:
Java has a known caveat that requires an extra rpm file,
xorg-x11-deprecated-libs-6.8.2-31.i386.rpm, that sometimes is not
installed by default on an RHEL 5.0 machine. As the IxANVL installer
is a Java-based application, it is required that this file be installed
in order to function normally. Please refer to the Linux installation
notes below for a workaround to fix this problem.
Ixia Chassis OS: IxOS 9.00
Supported Test Interfaces
Network interface cards directly attached to a Linux or Windows PC
- Ethernet 10/100
- Gigabit Ethernet
Ixia Load Modules (port CPU required) accessed via Virtual Network Interface Card (VNIC)
10/100/1000 Ethernet Modules:
- LM100TXS8
- LM100STSXS2
- LM1000STXS4
- OLM1000STXS24
- LM1000STXR4
- LSM1000XMS12-01/LSM1000XMSR12-01
- ALM1000T8
- LSM1000XMV16-01/LSM1000XMV12-01/LSM1000XMV8-01/LSM1000XMV4-01
- LSM1000XMVR16-01/LSM1000XMVR12-01/LSM1000XMVR8-01/LSM1000XMVR4-01
- ASM1000XMV12X-01, non-Aggregate Mode
- ELM1000ST2
- LSM1000XMVDC16
- LSM1000XMSP12
- LSM1000XMVDC12, LSM1000XMVDC8, LSM1000XMVDC4
- LSM1000XMVDC4NG, LSM1000XMVDC16NG
10G Modules:
- LSM10G1-01/LSM10gL1-01
- LSM10GXL6-01/LSM10GXL6-02
- LSM10GXM3-01/LSM10GXMR3-01
- MSM10G1-01
- LSM10GXM3-01/LSM10GXMR3-01
- LSM10GXM4-01/LSM10GXMR4-01
- LSM10GXM8-01/LSM10GXMR8-01
- LSM1000XMV8-01/LSM1000XMVR8-01
- LSM1000XMV12-01/LSM1000XMVR12-01
- LSM10GXM2XP-01/LSM10GXMR2-01
- LSM10GXM4XP-01
- LSM10GXM8XP-01
- LSM10GXM8-01/LSM10GXM8S-01
- LSM10GXM8NG-01
- Acceleron
- Novus10/1GE16DP
40G/100G Modules:
- HSE 40GE QSFP1-01
- FlexFE40QP
- LAVA AP40/100GE 2P
Novus ONE appliance
Novus ONE PLUS appliance
100G Modules:
- NOVUS100GE8Q28+FAN 8-port QSFP28 100GE
Ixia Licensing
IxANVL 9.27 ships with Ixia Licensing Utility 5.10
General Installation Notes
When you purchase IxANVL test suites, your Ixia Support representative sends
you an e-mail message containing a user name, a password, and an HTML attachment
that contains the link to your IxANVL installation file on the Ixia Web site.
The following procedure downloads the IxANVL installation file from the Ixia
Web site.
To download the installation file:
1. Select and open the attachment. Your Web browser displays the attachment
containing the link to your IxANVL installation file.
2. Right-click the link. A context menu appears.
3. Choose the command that allows you to save the target (your IxANVL
installation file). A dialog box appears, prompting you for the user name and
password from the email message.
4. When prompted, type your first and last name and the password. The File
Download dialog box appears.
5. Click Save.
6. When prompted for the target location, browse to the desired folder. The
IxANVL installation file is downloaded and stored in the target location.
Windows Installation Notes
The IxANVL installation file is supplied to you (either via a download or on the
IxANVL installation CD) as an executable named anvl-{release}.r-branch-Install.exe,
where {release} is the IxANVL release number. For example, for release 9.27,
the executable is 9.27.1.r-Install.exe.
Execute the following steps to install IxANVL on a Microsoft Windows machine:
1. Simply execute the installer executable by double-clicking the file. A
welcome dialog will be presented. Click Next to proceed.
2. Carefully read the End User License for Ixia Software. If you accept its
terms, select "I accept..." and click Next.
3. The install destination dialog box appears. Browse for the intended location
of this installation, and then click Next.
4. The pre-installation summary appears. Verify the installation information.
If the summary is correct, click Install.
A progress bar displays the IxANVL installation progress. A second progress
bar displays the progress of the Ixia licensing.
You can remove/uninstall the software by using the standard Microsoft Windows
Add/Remove Programs applet.
NOTE: IxANVL supports US English versions of the Windows operating system.
Although IxANVL may run on other versions of Windows OS, these other
versions are not officially supported by Ixia. If you attempt to install
or run IxANVL on any version of Windows OS other than the US English
version, IxANVL installation or operation may fail.
NOTE: When IxANVL is started in Windows 7, Windows 2008, Windows 2012, Windows 10 for the
first time, it requires to be started as "Run as administrator".
Linux Installation Notes
The IxANVL installation file is supplied to you (either via a download or on the
IxANVL installation CD) in a compressed format called gzip. It is named:
anvl-{release}.install.tar.gz, where {release} is the IxANVL release number. For
example, for release 9.27: anvl-branches-9.27.1.r.Install.tar
NOTE: Refer to IxANVL and VNIC user guide - CentOS 6.5 for prerequisite and installation
steps for IxANVL and VNIC in CentOS 6.5.
NOTE: Occasionally, there are display issues when running the installation with
some X-windows-based PC clients. In these cases, it is recommended to use
the console (command line) installation mode. In particular, there seems
to be a performance issue with some versions of Exceed. When using Exceed,
updating your Window Manager property value in 'XConfig/Screen Definition/
Screen 0' to be 'Native' may resolve the issue.
1. Before you can install IxANVL, you must extract the installation file. To
extract the IxANVL installation file:
a. Use the following command to gunzip the TAR.GZ file:
gunzip anvl-{release}.install.tar.gz
The result of this operation is a TAR file named:
anvl-{release}.install.tar
b. Use the following command to unTAR the TAR file:
tar -xvf anvl-{release}.install.tar
The result of this operation is the IxANVL installation file:
anvl-{release}.install
For example, for release 9.27:
anvl-9.27.1.r-branch.install
2. To install IxANVL
a. Login as root (or use the su command to switch to the root account).
3. Run:
./anvl-{release}.install
The installer displays its initialization window.
NOTE: Only the root account can install IxANVL.
NOTE: If you are using a text-only window, for example, Telnet, use the
-console option to run the installer in console mode.
Upon completion of the initialization, the Welcome dialog box appears.
Click Next to continue. The License Agreement dialog box appears.
4. Carefully read the End User License for Ixia Software. If you accept its
terms, select "I accept..." and click Next.
5. The Directory Name dialog box appears. Browse for the location of this
installation, and then click Next.
NOTE: Clicking Next here implies that you accept the terms of the End User
License.
6. If this is an upgrade, the installer will move the data for the original
installation to this location.
7. The pre-installation summary appears. Verify the installation information.
If the summary is correct, click Install.
A progress bar displays the IxANVL installation progress. A second progress
bar displays the progress of the Ixia licensing.
8. When installation is complete, the Summary information dialog box appears.
Click Finish.
Note: The IxANVL product is going to use a new Licensing mechanism called ILU.
Details of how the ILU is installed and used can be found in Chapter 6 of
the "ANVL Getting started guide" and the "Ixia Licensing Management User Guide"
Note: For this set of test suites to run (ipsec-ah, ipsecv6-ah , ipsec-esp, ipsecv6-esp, ike, ikev2,
ikev2-ipv6, ike-ipv6, tc8-l1l2-tests, eapol-a, eapol-s) user needs to install the 3rd Party Installer
alongwith IxANVL installer.
Note: For CentOS 7.5, the interface name should be changed from default one to eth0. Ixia License Server needs an interface named eth0 to function.
Contact List Change: 4150211; Date: 2013/09/24 |
USA, Canada and Latin America Customer Support
|
|
Europe, Middle East, and Africa Customer Support
|
|
India Customer Support
|
|
China Customer Support
|
Hours: |
09:00 - 18:00 local time (Beijing time), Monday through Friday |
Email: |
support-china@ixiacom.com |
Phone: |
400-898-0598 (Greater China region) |
Phone: |
+86-10-5732-3932 (Hong Kong customers) |
Fax: |
+86-10-8454-9198 |
|
Asia Pacific Customer Support
|
|
Japan Customer Support
|
Hours: |
09:00 to 17:30 local time (Japan), Business days |
Email: |
support-japan@ixiacom.com |
Phone: |
+81-3-5326-1980 |
Fax: |
+81-3-3348-7733 |
|
Please refer to our website at http://support.ixiacom.com/support-services/product-support/user-guides.
You will be required to provide a login and password to enter this section of
the web site. If you do not have a username and password, please forward your
request to: mailto:support@ixiacom.com.
IxANVL 9.27 Features
IxANVL-BGPSR-TE |
A new test suite is added in 'Segment Routing Test Suites' family covering 'BGP SR-TE Policy'. The test suite covers 34 test cases from draft-ietf-idr-segment-routing-te-policy-08 |
IxANVL-EtherCFM |
Test Case 17.3 - CCM Interval for the Continuity Check Message sent from IxANVL is increased to 10 second |
IxANVL-ISIS-SRv6 |
A new test suite is added in 'Segment Routing Test Suites' family covering 'ISIS SRv6'. The test suite covers 38 test cases from draft-ietf-lsr-isis-srv6-extensions-08 |
IxANVL-TC8-SOMEIP-ETS |
SOMEIP-ETS Test Suite is enhanced with 28 new test cases. |
IxANVL-TC11
Bug Number |
Notes |
1546685 |
For Automotive Test Suite TC11, Test Cases TIME_002 and TIME_004 are not supported.
|
IxANVL-IGMPV3
Bug Number |
Notes |
1541269 |
Test Case 8.7 - Added a delay between Multicast Group Join
|
IxANVL-OSPF
Bug Number |
Notes |
1542768 |
Test Case 2.5 - Priority field in Hello Message sent from IxANVL-2 is updated to be lesser than that of DUT to have correct DR election
|
IxANVL-TC11
Bug Number |
Notes |
1541439 |
Fixed transmission issue in test 1.20.
|
1541440 |
Test cases 1.14 and 1.15 now have modified test method with dut verify script added.
|
1544690 |
Test case 6.1 and 6.2 now correctly validates received frames
|
1544699 |
Framelength is corrected to be 64 when sent in test case DIAG_004.
|
1544703 |
Verification of IP packet is corrected in test FILT_016.
|
1544788 |
Test case 6.3 is modified a bit and TCL script is fixed so that it correctly sends PTP sync frames and calculate the correction field.
|
1546661 |
Test 9.7, 9.8, 9.14 now sends frames to correct interfaces
|
1546662 |
Test 9.6 can now listen for less than 1 second
|
1546664 |
Test case 2.14 now follows proper test method as described in Test Specification
|
1546665 |
Test cases 7.6 and 7.7 now do not get into any looping error.
|
1546666 |
Test case 7.7 now follows correct test method
|
1546667 |
Test case 10.8 now receives packets correctly
|
1546668 |
Test case 1.2 now correctly receives packets with expected vid
|
1546673 |
Test cases 7.8 and 7.12 now does correct analysis of received traffic
|
1546674 |
Test case 10.1 method is updated.to match test specification
|
1546676 |
GEN_017 test is fixed so that correct DA address is passed to traffic script.
|
1546679 |
Test 1.20 is fixed now by fixing the corresponding traffic script
|
IxANVL-TC8-SOMEIP-ETS
Bug Number |
Notes |
1546552 |
Test Case 4.26 - Event group id set to [PARAM-UNKNOWN-EVNT-GRP-ID].
|
1546555 |
Test Case 4.21, 4.24, 5.6 - Modified the expectation of the test method.
|
1546567 |
TTL field of Offer Service Message is now set to the correct value taken from parameter file
|
1546660 |
Test Case 24.8 - Modified SYN packet with new sequence number after reset assuming it as a new connection.
|
IxANVL-TCP
Bug Number |
Notes |
1540205 |
Test Case 16.20 - Non-Zero IP Identification validation is updated
|
1540702 |
Test Case 8.18 - ANVL checks flag value correctly and waits for the actual ACK
|
IxANVL-UDP
Bug Number |
Notes |
1540203 |
suite-setup script call is added in the test suite
|