IxCatENodeBSimRange

Extends IxCatRangeBase

DESCRIPTION

This class has no description.

OPTIONS

Parameter Description
divisionMode
Division Mode used by the eNB Range.
String, default = ""
Choices:
0 - FDD
1 - TDD
dlEARFCN
The value used for FDD DL EARFCN IE in the X2 Setup message. (Range 0-65535)
Integer, max = 65535, default = 0
dlTransmissionBandwidth
The value used for the FDD DL Transmission Bandwidth IE in the X2 Setup message.
String, default = "0"
Choices:
0 - bw6 (default)
1 - bw15
2 - bw25
3 - bw50
4 - bw75
5 - bw100
dscpValue
Differentiated Services Code Point (valid values 0 - 63)
Integer, max = 63, default = 0
echoRequestT3
Integer, default = 3
enableEchoRequest
Set to true to send echo request
Boolean, default = False
enableGrouping
When HeNB Id Grouping is enabled, the eNodeB Global Id is calculated based on the number of HeNBs, the group increment and the number of members in the group.
The last 8 bits of the eNodeB Global Id represent the group member, with the first group member having a member Id of 0. The first eNodeB Global Id of each new group
is incremented by 256.
Boolean, default = False
enableS1SetupFailureTolerance
Enable S1 Setup Failure Tolerance for this range.
Boolean, default = False
enodebCount
Number of eNodeBs
Integer, default = 1
eNodebGroupIncrement
When HeNB Id Grouping is enabled, the Group Increment value is added to the eNodeB Global Id for each new group.
Integer, min = 256, default = 256
eNodebGroupMembers
When HeNB Id Grouping is enabled, the last 8 bits of the Global eNodeB Id are used for the group member Id. The group member Id starts at 0 for each
group.
Integer, max = 255, default = 64
eUtranCellIdentifier
Macro eNodeB Cell:
The 28 bit E-UTRAN Cell Global Identifier (CGI) for Macro eNodeBs consists of the 20 bit Macro eNodeB Id and this 8 bit Cell Identifier.
This field is not used for Home eNodeBs (for which the 28 bit E-UTRAN CGI is the same as the 28 bit Home eNodeB Identifier).
String, default = "1"
globalIdType
String, default = "1"
Choices:
0 - Home
1 - Macro (default)
homeMCC
Mobile country code for the eNodeB's home network
String, default = "226"
homeMNC
Mobile network code for the eNodeB's home network
String, default = "10"
loadIndication
Configuration for Load Indication message
Reference to IxCatENodeBSimLoadIndication
macroENodeBStartID
The starting Global eNodeB Identifier for this range of eNodeBs.
For Macro eNodeBs, the valid range is 0-1048575.
For Home eNodeBs, the valid range is 0-268435455.
The Global eNodeB Identifier is part of the E-UTRAN Cell Global Identifier, which is one of the following:
o 28 bits of Home eNodeB Id
o 20 bits of Macro eNodeB Id + 8 bit Cell Identifier
For Macro eNodeBs, the Macro Id is incremented and the Cell Id portion (last 8 bits) remains constant.
Each IxLoad eNB supports only a single cell.
String, default = "5000"
mlbResourceStatusReport
Reference to IxCatENodeBSimResourceStatusReport
mmePoolList
The MME Pools associated with the eNodeB.
List of IxCatENodeBSimMMEPoolEntry objects
multiCell
Allow the UE to visit multiple cells within the same eNodeB (for Tracking Area Update)
Boolean, default = False
physicalCellIdentifier
Starting Physical Cell ID for this range of eNodeBs (Range 0-503)
Integer, max = 503, default = 0
s1SetupFailureTolerance
S1 Setup Failure Tolerance:
The maximum number of S1 Setup procedure failures allowed during Apply Config (as a percentage).
Apply Config will fail if a greater percentage of failures occurs than the failure tolerance value.
NOTE: Each port must have at least 1 eNodeB from each eNodeB range with a valid S1 link, even if the tolerance is set to 100%.
Integer, max = 100, default = 0
sctpPort
Source SCTP port for control plane messages (0 for random)
Integer, max = 65535, default = 36412
sharedMCC_1
Mobile country code for the eNodeB's shared network
String, default = ""
sharedMCC_2
Mobile country code for the eNodeB's shared network
String, default = ""
sharedMNC_1
Mobile network code for the eNodeB's shared network
String, default = ""
sharedMNC_2
Mobile network code for the eNodeB's shared network
String, default = ""
startSubscriberId
Start Subscriber ID for this range
Integer, default = 100
trackingAreaCode
Tracking Area Code (Hexa: 0000 .. FFFF)
String, default = "1011"
ulEARFCN
The value used for FDD UL EARFCN IE in the X2 Setup message. (Range 0-65535)
Integer, max = 65535, default = 0
ulTransmissionBandwidth
The value used for the FDD UL Transmission Bandwidth IE in the X2 Setup message.
String, default = "0"
Choices:
0 - bw6 (default)
1 - bw15
2 - bw25
3 - bw50
4 - bw75
5 - bw100
useDataIP
Use "Data Plane" IP for "Control Plane"
Boolean, default = False
x2eNodeBList
The X2 ANR eNBs associated with the IxLoad eNodeB.
List of IxCatENodeBSimX2eNodeBEntry objects