Ixia Software Release Notes
IxOS 9.45
Build Number: 9.45.4500.7 (Oct 2023)


About This Release

Welcome to IxOS 45 Release.
IxOS 9.45 introduces IxLoad support on the APS100/400GE series appliances, specifically the APS-M1010 controller and of APS-ONE-100 compute node. 
With the addition of IxLoad support, the APS100/400GE series appliances now reach new heights in hyperscale encryption performance and scalability,
setting industry benchmark standards for key performance indicators like HTTPS Connection rate, HTTPS Concurrent Connections, HTTPS Throughput,
and IPSec single tunnel throughput, further outpacing the competition. Please refer to the 'What is New' section for a complete list of all the new features.

Application Compatibility

 The following application releases support IxOS 9.45:
Application IxOS 9.45
BPS Not Supported
HLTAPI Not Supported
IxANVL Not Supported
IxLoad 9.45
IxNetwork Not Supported
IxVM Not Supported
Licensing 5.60
Metronome Not Supported
Wireshark 3.2.6
In addition, current interoperability and compatibility coverage for IxOS 
9.45 can also be retrieved using the on-line compatibility tool.


Licensing

Ixia Licensing

Any chassis which runs IxServer must have an IxOS license installed on it. 
IxOS 9.45 ships with Ixia Licensing 5.60, which is installed automatically along with IxOS Installation.

Some of the key benefits of this new licensing system are:
  - Supports Keysight's new KSM Licensing structure ( refer to Licensing Software Upgrade Required Customer Notice )

Installing a License

Ixia Licensing 5.60 upgrades Ixia Licensing 5.50 and prior versions. 
Once upgraded, Ixia Licensing cannot be downgraded to previous versions. 

If upgrading from the Ixia Registration Utility (IRU) used in IxOS 8.00 and earlier releases, note that 
automatic license migration is no longer possible. Please contact Support to assist you with the upgrade and with license retrieval.

For more information about the IxLicensing system, please refer to the "Ixia Licensing Management User Guide" 
provided with the Ixia software, or downloadable from the Ixia web site.


Installation Notes

Installation on APS-M1010 controller

APS-M1010 controller will comes pre-installed with IxLoad KCOS component. For details and reinstallation, please refer to APS installation guide available on the IxOS Software Downloads & Documentation

Installation on XGS2-SD and XGS12-SD chassis

Starting from IxOS 8.40 EA, the XGS2-SD and XGS12-SD chassis can optionally be converted to run Native IxOS, 
for improved stability and performance. The conversion removes the Microsoft Windows Operating System, and 
replaces it with IxOS running natively on the chassis. Once complete the chassis are effectively converted to 
XGS2-SDL and XGS12-SDL. For more information, including the conversion process procedure, please read 
the Converting XGS2-SD and XGS12-SD Chassis to Native IxOS.pdf document available on IxOS Downloads And Update page.

Starting from IxOS 9.00, XGS2-SD and XGS12-SD chassis can optionally be converted to run Windows 10 Pro 64-bit, 
which allows the installation of the latest security and stability updates from Microsoft. For more information,
including the conversion process, please read the Windows 10 Upgrade Guide and  the Windows 10 Datasheet.  
Requires the purchase of IXIA IXOS AND WINDOWS 10 FIELD UPGRADE 943-0014.

Installation on PSOne, XGS2-HS and XGS12-HS chassis

Starting from IxOS 9.00, IxOS installation is no longer supported on the PSOne, XGS2-HS and XGS12-HS chassis with 
Windows OS. To install IxOS and compatible Ixia Applications on these platforms, the management operating system must
first be converted to Native IxOS 9.45. The conversion procedure is described in Converting_XGS_and_PSOne_to_Native_IxOS.pdf,
which can be downloaded from IxOS 9.45 Downloads And Update page.

NOTE:
     -For security reasons, we recommend changing the default passwords for chassis.

Installation Requirements On Windows

IxOS 9.45 installation requires 13 GB of free space on chassis' system drive and 5.5 GB of free space on client's system drive.
IxExplorer 9.45 installation requires 2.5 GB of free space on client's system drive.



NOTE:
   - IxOS installer automatically installs a Microsoft Hotfix 2921916 (if not already installed) for an issue due to which 
     "Untrusted publisher" dialog would appear when installing IxOS on Windows 7.

Operating System Support

Windows Client PC: 
  - Windows 2008 Server 64-bit
  - Windows 7 Enterprise 32-bit (Build 7601)
  - Windows 7 Professional 32-bit (Build 7601)
  - Windows 7 Professional 64-bit (Build 7601)
  - Windows 7 Ultimate 32-bit (Build 7601)
  - Windows 2012 Server Standard R2 64-bit
  - Windows 8.1 Enterprise 32-bit and 64-bit (Build 9600)
  - Windows 10 64-bit (Build 21H2)

  The following versions of Windows operating systems are no longer supported on the client:
     - Windows Vista Enterprise SP2 32-bit and 64-bit - starting with IxOS 8.21 EA
     - Windows XP Professional 32-bit SP3 - starting with IxOS 8.30 EA

UNIX Client PC: 
  - Fedora Core 14.0 and above
  - RedHat Enterprise 5.0 and above
  - Centos 6.0 and above
  - Ubuntu 16.0 and above

  Other versions of UNIX platforms may operate properly, but are not officially supported.

VMware
  - Server 1.0.2
  - Server 2.0

Windows Chassis
  - Windows 10 Pro Version 22H2
  - Windows 7 Ultimate 32-bit

  NOTE: IxOS is no longer supported on a Windows XP Professional Chassis, starting with IxOS 9.00.

  Languages supported are English, Chinese (traditional and simplified), French, German
  Hebrew, Italian, Japanese, Spanish and Swedish.

Supported Chassis

This release supports the following chassis:
 - XGS12-SD Windows 10 and Windows 7
 - XGS2-SD Windows 10 and Windows 7
 - XGS12-SDL
 - XGS2-SDL
 - XGS12-HSL
 - XGS2-HSL
 - AresOne
 - AresONE-S
 - AresONE-800G
 - Novus ONE PLUS 
 - Novus ONE
-  PerfectStorm One

Installation Features

The IxOS installation program offers the user a selection of four installation 
options: Client, Server, Demo Server and Tcl Server. The 
Server option is normally chosen for installation on Ixia chassis. The Demo 
Server option should NOT be chosen for chassis installations: it is used for 
client installations.

IxServer on Windows Chassis

In IxOS 9.00 High Performance Mode was introduced to the Windows chassis as an option, with the alternative to revert to Legacy Mode to support a wider range of load modules.
Besides significantly improving performance in multi-user test beds, High Performance Mode also enables chassis STAR or Metronome synchronization capability between Native IxOS and Windows Chassis.
With 9.10, only High Performance Mode exists, and it has been enhanced to support the wider range of load modules.  The Native IxOS chassis has always supported High Performance mode. 

Startup Configuration Options

There are three options offered for configuring IxOS server startup:

1. Service: A Windows Service for IxServer (or TCL Server) will be created which can be started/stopped
    from Windows Service Control Manager. Desktop Shortcuts and IxServer User Interface are not available.
    Any configuration of IxServer or TCL Server requires user to stop the service, manually invoke server
    from Start Menu shortcuts, close the server and restart service.
2. Startup: IxServer starts when user logs on to the chassis or when it is rebooted.
3. Manual: IxServer or TCL Server can only be started or stopped manually from
    Desktop or Start Menu shortcuts.
 
    NOTE:
       - Telnet connectivity is unavailable when TCL Server is configured to run as a service.
       - Demo Server is configured to operate manually even if service option is selected.

Tcl Version Option

IxOS 9.45 is shipping with Tcl 8.5 and 8.6. Both of them will be installed and the option
of using either of the version can be set for usage as follows:
1. On Windows Chassis, open TCL Server and select appropriate TCL version from options.
2. On Windows Client, select appropriate TCL version from Desktop or Start Menu shortcut.
3. On Native IxOS Chassis, login to IxOS CLI using SSH and execute:    set tcl active-version 8.x
4. On Unix Client, execute a script inside installed directory:    ./bin/set_tcl_active_version.sh 8.x

Chassis Management Console

 
Chassis Management Console (CMC) is a web application that provides access to Ixia Native IxOS Chassis and its components 
(i.e. load modules and ports) and enables users to control and monitor the chassis by means of any client computer connected to it. 
CMC is supported on following browsers:
Application Version
Google Chrome 75 or newer
Mozilla Firefox 67 or newer
Microsoft Edge 38 or newer
Apple Safari 12.1.1 or newer

UNIX Client Installation Notes

Using .bin Installer:

This installs packages for IxOS TCL API and Ixia TCL Interpreter. If you are updating an existing 
installation, be sure to run the installer as the same user who initially installed the software. Always 
run the uninstaller prior to removing any files manually. If installing as the root user and install 
location is a network-mounted file system, ensure the root user has write permission to the file system.

To proceed with installation, perform following steps (Note: the binary file name 'IxOS9.45.XXX.XXXLinux.bin' 
is used in the example below. In most cases, the file name will be different):

1. Copy the IxOS9.45.XXX.XXXLinux.bin file to the system.
2. Make the binary executable if it is not already:    chmod +x ./IxOS9.45.XXX.XXXLinux.bin
    Also, make sure target installation directory has full permissions granted.
3. Execute the IxOS installer file:    ./IxOS9.45.XXX.XXXLinux.bin
4. When the installer prompts, select appropriate Tcl version (e.g. 8.5 or 8.6)
5. Follow the installation prompts to complete the installation.

If the installation fails, check that there is enough disk space on the system  by using the command: df -ak
There must be enough space in the /tmp folder (to extract the files), and in the target folder (where files are 
to be installed). If the /tmp dir does not have enough space, specify the dir by setting IATEMPDIR environment 
with path to the folder where you have enough free space. The following example show the use of the options:

export IATEMPDIR=/tempdir
./IxOS9.45.XXX.XXXLinux.bin

Using .tar.gz:

This installs packages for IxOS TCL API only. To install, perform the following steps:

1. Create a destination folder and extract contents of .tar.gz file into it. e.g. /export/home/ixos9.45
2. After extraction, set the following variables (please replace sample path with original path):
        IXIA_HOME=/export/home/ixos9.45
        IXIA_VERSION=9.45.XXX.XXX
        TCLLIBPATH=/export/home/ixos9.45/lib
3. Optionally, specify the following environment variables to specify the location of logs, samples and results files for IxOS:
	IXIA_LOGS_DIR=$IXIA_HOME/logs
	IXIA_RESULTS_DIR=$IXIA_HOME/results
	IXIA_SAMPLES=$IXIA_HOME/samples
	IXIA_TCL_DIR=$IXIA_HOME/lib
4. If the Tcl option was installed with an IxOS installation, add Ixia's bin 
    and lib directory to the PATH and LD_LIBRARY_PATH variable in order to use it. 
    For example:
        IxiaLibPath=$IXIA_HOME/lib
        IxiaBinPath=$IXIA_HOME/bin
        PATH=$IxiaBinPath:$PATH
        LD_LIBRARY_PATH=$IxiaLibPath:$LD_LIBRARY_PATH

Multiple IxOS versions

Multiple IxOS versions can co-exist on an Ixia Chassis or client. Installing another IxOS version does not affect the existing versions.
On Windows Chassis, to set active IxOS version, users are required to close any running instance of
IxServer or TCL Server and start the intended IxServer version from Start Menu or Desktop Shortcuts.
On Native IxOS Chassis, users can login to IxOS CLI via SSH and set active IxOS version using
the command: set ixos active-version 8.x.x.x

NOTE: Any card, port, stream, etc., files generated by IxOS are forward compatible but not backward compatible. 

Tcl/Tk Support for Client Applications

Tcl Server was first supplied free of charge starting with IxOS 3.80 EA. 
Installation of this feature is optional; it should only be installed if 
required for specific application.
 
Installation and operation of the Tcl Server is required for IxChariot when 
running hardware performance pairs, for IxANVL when running VNIC (Virtual 
Network Interface Card) and for IxAuthenticate. The Tcl Server can be installed 
on either the Ixia chassis or a separate Windows workstation. 

The following limitations exist with respect to Wish and Tcl shell support:

   Tcl shell does not run on any version of Windows with Ixia software. Under
   Linux or Solaris, the Tcl shell runs on any version of Tcl greater than or 
   equal to 8.3.

How to Report Problems

Ixia Headquarters
+1 877 367 4942 - Toll-free North America
+1 818 871 1800 - Outside North America
+1.818.871.1805 - Fax
www.ixiacom.com/contact/info
Support
Global Support +1 818 595 2599

support@ixiacom.com

APAC Support +91 80 4939 6410

support@ixiacom.com

Australia +61-742434942

support@ixiacom.com

EMEA Support +40 21 301 5699

support-emea@ixiacom.com

Greater China Region

+400 898 0598

support-china@ixiacom.com

Hong Kong +852-30084465

support@ixiacom.com

India Office +91 80 4939 6410

support-india@ixiacom.com

Japan Head Office +81 3 5326 1980

support-japan@ixiacom.com

Korea Office +82 2 3461 0095

support-korea@ixiacom.com

Singapore Office +65-6215-7700

support@ixiacom.com

Taiwan (local toll-free number) 00801856991

support@ixiacom.com


Additional Documentation

Please refer to our website at https://support.ixiacom.com/ixos-945.

You will be required to provide a login and password to enter this section of 
the web site. If you do not have the username and password, please forward your 
request to support@ixiacom.com.

Field Notices

Laser Warnings

The 10G load modules may use a Class III laser. Precautions should be 
taken to prevent personal injury. The spring-loaded safety cover should always be 
securely in place over the port when there is no cable installed. Avoid exposure
and never look directly into an open port aperture.

Inserting / Removing Load Modules

Modules in the XGS12-SD, XGS12-HSL, XGS12-SDL, XGS2-SD, XGS2-HSL, XGS2-SDL can be inserted/removed while the chassis is still operational.  

For all chassis types, use caution when inserting or removing multi-slot modules 
to evenly insert and remove. Load modules are tightly spaced; avoid contacting 
the adjoining modules while inserting and removing.

Safety Notice Regarding Ixia Load Modules

WARNING: In order to prevent accidental injury to personnel, do not leave transceiver 
(SFP/SFP+/QSFP/QSFP28/CXP/CFP4) cages uncovered on Ixia load modules. When transceivers 
are not installed, port end caps (Part No. 503-006) must be used. The metal edge of 
the transceiver cage is SHARP. To avoid injury, ALWAYS keep the transceiver cage covered.
   
Contact Ixia Technical Support to obtain end caps. Please reference Ixia Product
safety notice Part No. 913-0715 Rev A, June 2009. For additional information
refer to Chapter three of the IXOS Getting Started Guide under the section, 
Notes, Cautions and Warnings.

Use Ejector Tabs Properly

Ejector tabs on load modules are to be used only to eject a load module from
the chassis backplane connector. They are not designed to support the weight
of the load module. Ejector tabs can bend or break if used improperly as handles
to push, pull, or carry a load module.

What's New in IxOS

 

Notes

Stack Manager protocol support for IPv4, IPv6, IPsec, DHCP v4/v6.

Support for HTTP/1.0/1.1, HTTPS, DNS, AppReplay, FTP, StatelessPeer (Load mode).

Support for HTTP/2 (beta).

Support for the APS-M1010 controller and APS-ONE-100 compute node.

 


Known Issues List

 

Bug Number Notes

IXOS-8027

[NOVUS10/5/2.5/1/100M16DP] Frames are not received on ports with line loopback enabled for speeds 1G, 2.5G and 5G

IXOS-8642

[NOVUS10/5/2.5/1/100M16DP] Sending frame preemption verify/response frames may result in the loss of some of these types of frames if frames are configured with Bad CRC

IXOS-9720

[AresONE 800GE-QDD-C] The latency variance for different frame size is not as expected.

IXOS-9837

[IxOS]When upgrading the build from IxOS 9.10 or older builds to new ones using the Web UI of a chassis having 9.20 or newer builds, it falls back to 'Unknown' instead of 'primary/secondary' and throws error. Workaround is to install IxOS build from CLI on the chassis or using Web UI of the chassis directly.

IXOS-10053

[AresONE 800GE-QDD-C] Partner port goes down on configuring loopback mode on the port.

IXOS-10203

[VE]Starting with this release we have reduced the DHCP Client timeout to 5 seconds in all VMs. If the DHCP Server in your network is slower, please raise this timeout to a higher value.

IXOS-10209

[AresONE 800GE-QDD-C] Alignment marker mapping is not accurate.

IXOS-10210

[AresONE 800GE-QDD-C] Sometimes, ports may go to bad state and hardware fault can be seen during mode switch. Ports automatically recover by reloading FPGAs.

 

 


 

Resolved Defects List

 

Bug Number Notes

IXOS-1200

[TCL] Writing to write-only registers via TclHAL is not allowed without setting a read-write property.

IXOS-3705

[IxServer]
On rare occasions, connections to IxServer fails while running automated regressions tests for long duration due to the multiple idle connections to the ixProxy.

IXOS-7833

[Novus10GDP]
DUT port link toggles on simulating port link down on Novus port

IXOS-7844

[IxOS]Banked page CMIS register access is not operational in IxExplorer and TclHAL.

IXOS-7961

[IxOS] If a transceiver is removed while being initialized, the port keeps on waiting through the advertised initialization time until timeout is reached.

IXOS-7963

[AresONE S400GD] Data Integrity errors are seen for some specific configurations.

IXOS-8379

[VE]Ports that are attached to the Virtual Test Appliance after the first boot appear as down.

IXOS-8575

[Miscellaneous] TCL API 'stat set' fails for load modules present on specific slots

IXOS-8582

[TCL] Certain TCL APIs are not working when providing input in a different format.

IXOS-8633

[Miscellaneous] The trace files are very large and too many files saved to a single folder causes disk space gets full.

IXOS-8793

[CS100GE2Q28NG+25G+40G+50G] IxExplorer crashes when clicking on AutoNegotiation tab for 4x25G and 2x50G speed modes.

IXOS-8806

[Miscellaneous] In certain scenarios, timeout error is seen when trying to add a chassis.

IXOS-8850

[IxExplorer]
Packet Group ID offset is incorrect in the capture on enabling "Use PG config. from Receive Mode of this port" option under steam properties.

IXOS-9185

[IxExplorer] When Vlan ID counter overflows to the CFI field in the ethernet frame on incrementing it over maximum supported value of 4095.

IXOS-9359

[800GE] High values of threshold frame count cannot be set when testing Rate Monitoring with PGID count greater than 2 on 800GE.

IXOS-9364

[Miscellaneous] IxServer doesn't boot after setting Secured Mode and IxServer restart

IXOS-9538

[TCL] TCL API igmp decode does not work when using Fully Qualified Port Name (FQPN) port format.

IXOS-9861

[CLI]
Proxy settings are getting lost on system reboot.

IXOS-10075

[Miscellaneous] On switching back the IxOS build to IxOS 9.20 or older versions, IxOS CLI banner may display the Chassis Status as "NOT READY" due to the cloudagent service not running. This error is not fatal and can be ignored, IxServer is fully functional.

IXOS-10159

[NOVUS10/1GE32S]
Port link doesn't comes up on performing simulate cable disconnect from IxNetwork UI

IXOS-10163

[VE]Operation of changing admin user password via the Virtual Chassis or Virtual Test Appliance CLI results in error.

IXOS-10164

[VE]In case of disk space running out, enable the IxOS auto-log-cleanup option starting with this release. This option will automatically cleanup all IxOS logs every 5 days. This option can be turned off or have its recurrence interval modified from the Virtual Chassis or Virtual Test Appliance CLIs.

IXOS-10165

[VE]Virtual Machines created with the Deployment Wizard have their management interface configuration incorrectly changed from Static IP to DHCP.

IXOS-10166

[VE]Virtual Test Appliance start up fails to start services due to a slow boot process. This was happening on lower performance servers.

IXOS-10167

[VE]Diagnostics tool is incorrectly reporting disk space on the Virtual Test Appliance or Virtual Chassis.

IXOS-10173

[Infrastructure] Management pages cannot be added to CMIS 4/CMIS 5 transceivers.