Chapter 39: IxVM


IxVM is a software-based test platform that enables you to turn standard Linux Ethernet ports into virtual Ixia ports. IxVM can create virtual Ixia ports from the virtual Ethernet ports on a Linux virtual machine (VM), or from the physical Ethernet ports on a physical Linux server.

To configure the traffic generated by the virtual Ixia ports, you use compatible versions of Ixia applications such as IxExplorer, IxNetwork, and IxLoad. When you use these applications, working with a virtual Ixia port is the same as working with a real chassis, with only a few minor differences.

IxVM offers the following benefits:

In this section:

Features

IxVM main features include:

Requirements

IxVM requires the following:

Hardware

IxVM Server: IxVM server requires Windows 7 32-bit.

ESX(i) deployments: IxVM runs on any virtualization server that ESX(i) supports.

KVM, Xen or other deployments: For KVM or Xen and bare-metal deployments, Ixia recommends a high-performance server with CPUs that include virtualization extensions such as Intel-VT or AMD-V. A high-end application server is available from Ixia - contact your Ixia sales representative for more information.

Hypervisor / Host OS

IxVM supports the following hypervisors or host OSes:

VM Operating Systems (Guest OS)

IxVM virtual ports can be created on any VM running one of the following operating systems:

Distribution Methods

IxVM is distributed using a variety of methods. The table below lists how IxVM is distributed for supported combinations of hypervisor and guest OS.
 
Guest OS Distribution Method
Hypervisor or Host OS
Ixia Kernel
RedHat/CentOS/SUSE
VMware ESXi 5.0
OVA/RPM
RPM
VMware ESXi 5.1
OVA/RPM
RPM
KVM (QEMU) over CentOS 6.3 64-bit
RPM/Self-extracting image
RPM
Xen over CentOS 5.6 64-bit
RPM/Self-extracting image
RPM

Note: The Ixia Kernel rpm should only be used for upgrading to newer versions of IxVM using the Deployment Wizard.

VM Discovery

Discovery Server discovers virtual Ixia ports, and adds them to the list of available ports in Ixia testing applications. You can download Discovery Server from the IxVM page of Ixia's website.

Update Utility

Deployment Wizard updates the IxVM platform with new versions of the IxVM software. You can download Deployment Wizard from the IxVM page of Ixia's website.

Ixia Application Software

The following applications are supported on the IxVM platform:

You can download all three from Ixia's website.

The following tables lists the Ixia applications you can run on each combination of hypervisor and guest OS:
 
Guest OS
Hypervisor or Host OS
Ixia Kernel
VMware ESXi 5.0
IxExplorer
IxNetwork
IxLoad
VMware ESXi 5.1
IxExplorer
IxNetwork
IxLoad
KVM (QEMU) over CentOS 6.3 64-bit
IxExplorer
IxNetwork
Xen over CentOS 5.6 64-bit
IxExplorer
IxNetwork

 
Guest OS
Hypervisor or Host OS
RedHat/CentOS 6.3 32-bit
VMware ESXi 5.0
IxExplorer
IxNetwork
VMware ESXi 5.1
IxExplorer
IxNetwork
KVM (QEMU) over CentOS 6.3 64-bit
IxExplorer
IxNetwork
Xen over CentOS 5.6 64-bit
IxExplorer
IxNetwork

 
Guest OS
Hypervisor or Host OS
SUSE LINUX ES 11 32-bit
VMware ESXi 5.0
IxExplorer
IxNetwork
VMware ESXi 5.1
IxExplorer
IxNetwork
KVM (QEMU) over CentOS 6.3 64-bit
IxExplorer
IxNetwork
Xen over CentOS 5.6 64-bit
IxExplorer
IxNetwork
CentOS 5.6 64-bit on bare metal
 

About the Red Hat and CentOS Kernels

RedHat Enterprise Linux 6.x and CentOS 6.x are based on the same kernel. RedHat Enterprise Linux requires a subscription, in return for which Red Hat Inc. provides support and other services. CentOS is the Community Enterprise edition, and is free. The same RPM packages can be compiled and installed on both RedHat and CentOS.

Licensing

The following are the licensing requirements of IxVM and its related Ixia components:

Licensed:

Note: All IxVM-enabled test applications such as IxVM Server, IxExplorer, IxNetwork/IxNetwork-FT and IxLoad use floating licenses, meaning that a specified license server stores a number of licenses that can be re-used alternatively by a number of installed test applications.
Each time a test application starts, one license is used from those available on the licensing server. This allocation process continues as more applications request licenses, until the pool of remaining licenses is depleted.
For each of the test applications, you specify the licensing server in the following locations:
  • For IxVM Server, specify the server host on the TOOLS > OPTIONS > GENERAL tab.
  • For IxNetwork-FT, specify the server host on the IxExplorer TOOLS > OPTIONS > LICENSE MANAGEMENT tab.
  • For IxNetwork, specify the server host on the FILE > TOOLS > LICENSING tab.
  • For legacy Network-FT TCL scripts, follow the instructions for setting the license server through IxExplorer / Network-FT. Once you set the Explorer / Network-FT license server, you can run your TCL scripts.
  • For IxLoad, specify the server host by clicking OPTIONS > LICENSE SERVER on the toolbar.
If you change the license server location in any of the test applications, you must restart the application for the new location to take effect.
The license server host must have the IxProxy service running on it to traverse any firewalls between the license server host and the hosts running the test applications. IxProxy is supplied with IxVM Server and must be manually started using the SERVICES - ADMINISTRATIVE tool of Windows.

Not Licensed:

Note: The new Subscription Licensing model for IxVM ports, will impose to have installed on the license server at least the same number of licenses as the number of ports from the virtual chassis.
For example, if on the virtual chassis there are 10 ports, then on the license server there should be at least 10 Tier-3 licenses.

The Ixia licensing process is described in the Ixia Licensing Guide.

IxVM Deployment Models

There are three general ways that you can deploy IxVM:

This section describes each method.

In this section:

vSphere Deployment

In an vSphere deployment, you use vSphere to create VMs based on the Ixia kernel template file (.ova).

In the figure below, the following components are present:

KVM Deployment

In a KVM deployment, the virtual Ixia ports are created on virtual machines running under the KVM hypervisor on a KVM server. The figure below shows the components used in a KVM deployment.

In the figure below, the following components are present:

XEN Deployment

In a XEN deployment, the virtual Ixia ports are created on virtual machines running under the XEN hypervisor on a XEN server. The figure below shows the components used in a XEN deployment.

In the figure below, the following components are present:

Bare-metal Linux Deployment

Although deploying IxVM as a series of VMs is the most typical scenario for using IxVM, it can also hosted on a bare-metal Linux server. The figure below shows the components used in a bare-metal deployment of IxVM.

In the figure below, the following components are present:

Windows components

The Windows components required to manage and use IxVM virtual cards can be installed in any of the following places:

Note: You cannot install the IxVM component on an Ixia chassis.

Installing IxVM Components on a Physical computer or Windows VM

To use a physical computer or Windows VM as the IxVM controller, install the following applications on the computer or Windows VM, making sure to select the options for IxVM support when you install them:

TCP/UDP Ports Required

The following ports are needed for communication between Windows VM and Linux VMs:

TCP

UDP

Windows VM ports

Windows VM ports are as follows:

Installing IxVM

The installation process for IxVM depends on the deployment type you are using:

Note: On Xen hypervisors, installing IxVM on a VM created without the self-extracting script file is not supported.

The following sections describe each method:

OVA-based Installation

The sequence for deploying IxVM on vSphere is as follows:

  1. Download and install VMware ESX(i) on your VMware server (if you have not already done so).
  2. If you intend to use a VM as the IxVM chassis controller, create a Windows VM in VMware, and install IxServer and the supporting applications on it.
  3. Download the Ixia kernel template (.ova) file, and use the template to create the one or more Linux VMs to host the virtual Ixia ports
  4. Configure Discovery Server.

The following sections describe each of these steps.

After you have completed the steps, you can begin using the virtual Ixia ports with your Ixia testing application.

Downloading and Installing vSphere

If you have not already installed VMware's ESX(i), you must install it on your server. ESX(i) is available free and has the same user interface as the enterprise versions of vSphere and vCenter Server.

Note: ESX(i) is a Type 1hypervisor -- a virtualization operating system. It is not a virtualization application that you can run on top of another operating system. If you install ESX(i), it replaces the existing operating system on your server

A video is available showing the ESX(i) installation process: http://www.youtube.com/watch?v=3UjSd8rbJvQ (http://www.youtube.com/watch?v=3UjSd8rbJvQ). Note the steps at the end of the video for configuring the password and IP address of the server.

  1. Access the VMware web site and register for a free account: https://www.vmware.com/tryvmware/index.php?p=free-esxi&lp=1 (https://www.vmware.com/tryvmware/index.php?p=free-esxi&lp=1)
  2. Download the VMware ESX(i) ISO image, and then burn it to a CD-ROM. Make sure that you save the ESX(i) license key.
  3. Power on your server and enter the BIOS setup utility.
  4. Enable all the virtualization features in the BIOS.
  5. In the BIOS, make sure that the boot order shows the CD-ROM first and the internal hard disk second.
  6. Insert the CD-ROM into your server's CD-ROM drive, save the changes to the BIOS and then reboot the server.
  7. Install ESX(i) on your server.
  8. On the computer that you will use to access the server, open a web browser and enter the server's IP address in the URL field.
  9. Install vSphere client on the computer.

Creating the Source and Destination Networks

Before you create and deploy the VMs, you should already have created the virtual networks that they will use. To create the virtual networks, you use vSphere client. You will need two networks:

On the Windows VM (virtual chassis):

Two networks are pre-configured on the Ixia kernel OVA:

During the process of creating the VMs, you map the source networks configured in the .ova template to the destination networks on your VMware server.

To create the networks, use the following procedure:

  1. Open vSphere client, and display the Inventory tab.
  2. Click the Configuration tab.
  3. In the Hardware pane, click Networking.
  4. Click Add Networking.
  5. The Add Networking wizard starts, and displays the Connection Type window.

  6. Click Virtual Machine, then click Next.
  7. The Network Access window displays

  8. Click Create a Virtual Switch.
  9. The Connection Settings window displays.

  10. In the Network Label field type a name, then click Next.
  11. Repeat for the additional vSwitches (networks).

Deploying the IxVM Appliances (OVAs)

The IxVM Ixia kernel is available as an Open Virtual Appliance (.ova) file, which is a template for a virtual machine. The .ova template creates a VM with a Linux kernel that has been modified by Ixia for greater performance in some testing scenarios. To use the .ova file, you use vSphere client to create a VM, and specify the .ova file as the template for the VM.

Note: Before you create and deploy the VMs, you must already have created the virtual networks that they will use in vSphere. See Creating the Source and Destination Networks on page 39-16.

To create a VM based on an IxVM OVA file:

  1. Download the .ova file from the Ixia website. Store them in a location where they can be accessed from the ESX(i) server.
  2. From the vSphere client menubar, choose FILE | DEPLOY OVF TEMPLATE.
  3. The Source window displays.

  4. Choose DEPLOY FROM FILE:, then click BROWSE, and select the .ova file. Click NEXT.
  5. The OVF Template Details window displays.

  6. Make a note of the Username and Password shown on the OVF Template Details window. The default usernames and passwords are:
  7. root/ixia123

    Click NEXT.

    The End User License window displays.

  8. Click ACCEPT to accept the license, then click NEXT.
  9. The Name and Location window displays.

  10. Enter a unique name for the VM, then click NEXT.
  11. The Datastore window displays.

  12. Select the data store where you want your VM files to be stored, then click NEXT.
  13. The Network Mapping window displays. On this window, you map the networks configured in the .ova template to the networks on your virtualization server.

  14. Map the template's networks to your VMware networks, then click NEXT.
  15. The Ready to Complete window displays, showing a summary of the deployment options you have selected.

  16. Choose one:
    • If you are installing using vSphere client with vCenter, the wizard displays windows enabling you to select the IP address allocation method. Choose the method you want to use.
    • If you are installing using vSphere client without vCenter, the VM is automatically created with IP address allocation set to DHCP. If you want to use static IP addresses, you must use the VM's console interface to specify the IP addresses of the VM after it boots. See Configuring static Addresses (see "Configuring Static Addressing" on page 2).
    • Review the final deployment details, then click FINISH. Allow the VM several minutes to deploy.

  17. Boot the VM.
  18. Repeat the deployment procedure for the remaining VMs that you want to create.

Configuring Static Addressing

If you created an IxVM template using vSphere without vCenter, the VM is automatically created with IP address allocation set to DHCP. If you want to use static IP addresses, you must use the VM's console interface to specify the IP addresses of the VM after it boots.

To configure a static address on a VM:

  1. In vSphere client, select the VM that you want to configure.
  2. Click the CONSOLE tab.
  3. A console session for the VM starts, and prompts you to login.

  4. Login to the VM with the user name and password configured on it when it was created.

Note: You can display the user name and password by clicking the Summary tab, then select Annotations, and then click Edit. Scroll through the window untill the user name and password displays.

  1. Start the vi editor and load the IP address script for the eth0 interface by typing the following command:
  2. vi /etc/sysconfig/network-scripts/ifcfg-eth0

  3. Type I or press the INSERT key to switch to edit mode.
  4. Change BOOTPROTO to static.
  5. Add a new line that contains the following:
  6. IPADDR=<ipaddress>

    where <ipaddress> is the address you want to assign to VM's eth0 interface.

    NETMASK=<mask>

    where <mask> is the netmask to be applied to the IP address.

  7. Close and save the file: Press ESC, then type: : W Q ! (colon, w(rite), q(uit), exclamation point).
  8. Repeat for the eth1 interface (edit the file ifcfg-eth1).
  9. Issue the following commands to bring the interfaces up:
  10. ifup eth0

    ifup eth1

Configuring Discovery Server

Use the following procedure to configure Discovery Server.

  1. Start Discovery Server using the following command:
  2. START | ALL PROGRAMS | IXIA | IXIA DISCOVERY SERVER | IXIA DISCOVERY SERVER

    Discovery Server starts, and minimizes to the tray.

  3. Double-click the DISCOVERY SERVER icon.
  4. Click the BROADCAST DISCOVERY tab.
  5. The Broadcast Addresses list contains the list of IP addresses configured in the VM. For some installations, this may include the address of the IxVM management port (the first LAN connection), and the second LAN connection. Discovery Server displays the IP addresses for all the network adapters configured on the Windows VM so that you can select the networks that you want to search for IxVM cards.

  6. Select the check box for the address of the IxVM card management IP port (typically, 10.0.0.x), and clear the check box for the second LAN connection.

Note: If you restart Discovery Server, the check boxes are reset to their default values.

Optimizing Performance

You may be able to improve performance by applying the following optimizations:

Power Management

In the ESX(i) server BIOS, ensure that Power Management is set to High Performance.

Hyperthreading

In vSphere, click the Configuration tab, then click Processors, and disable hyperthreading. Reboot the ESX(i) server.

Figure 39-1.

The Configuartion Tab

NIC Type

In vSphere, click the Hardware tab, and change the test NIC Interface types to VMXNET3.

Figure 39-2.

The Hardware Tab

Visit VMware's Networking Blog for more details on how to enable Jumbo Frames: http://blogs.vmware.com/networking/

KVM Installation

For KVM deployments, Ixia supplies IxVM in two forms:

Before Installation

Before you install IxVM:

Note: For details on the various switches the script accepts, run the script with the help switch before you run it to install IxVM:
./VM_IxVM_QemuKVM-<version>.sh -help 

Installing IxVM on KVM

  1. The script requires root-level privileges to run. Login to the KVM host using an account that has root privileges.
  2. Copy the VM_IxVM_QemuKVM-<version>.sh script to the KVM host. If you are copying using WinSCP, set the Transfer Settings to Binary mode .
  3. Make the script file executable:
chmod +x VM_IxVM_QemuKVM-<version>.sh 
  1. Set your path to the location where you want to store the VM (or use -d to specify a different path when you run the script).
  2. Run the script.
./VM_IxVM_QemuKVM-<version>.sh 
 

If you want to create the the VM in a different location, use the -d switch followed by the path:

./VM_IxVM_QemuKVM-<version>.sh -d <path>

The script starts, and prompts you for a name for VM.

  1. Enter a name for the VM, then press ENTER.
  2. The script displays a list of the bridges and virtual networks on the KVM host. You must choose two bridges or virtual networks:

    • one for the card management traffic
    • one for the generated test traffic
  3. Type the name of the bridge or virtual network you want to use for the management traffic, then press ENTER.
  4. Type the name of the bridge or virtual network you want to use for the test traffic, then press ENTER.
  5. The script unpacks the .img file and creates a VM in the current directory.

  6. If you are using Virtual Machine Manager (VMM), restart it before you start the new VM.
  7. The password for the VM's root account is ixia123.
    Note: In addition to the .img file, the script also creates an .xml file in
    /etc/libvirt/qemu/  
    
    that describes the VM's hardware configuration.
    If you delete the VM from VMM, only the .xml file is deleted; you must manually delete the .img file

KVM Tutorial

Introduction

KVM (Kernel-based Virtual Machine) is a full virtualization solution for Linux that takes advantage of CPU based hardware acceleration such as Intel VT or AMD-V. KVM itself exists as a kernel module and can be installed on a Linux system that has the supported set of Intel/AMD processors.

This document will demonstrate one use case of virtualization by leveraging the capabilities of the KVM Linux kernel extensions and open source virtualization software such as Red Hat's Virtual Machine Manager.

Other sources of information

http://www.linux-kvm.org

KVM Homepage.

http://libvirt.org
libvirt Homepage.
http://libvirt.org/docs.html
libvirt Documentation.

Before you begin

Please make sure that you have followed the first part of this guide: "Preparing Ixia Application Controller for KVM based IxVM" and ensure that you have VNC remote connectivity to your server.

Hardware requirements

This document focuses on the Ixia Application controller (also known as "AppServer") and the time of writing, this is a single-processor Intel Xeon (quad core), 24GB of DDR2 RAM, two integrated GbE LAN ports, and one slim DVD-ROM drive.

Software requirements

Time requirements

Start to finish, Windows 7 installation, IxOS and IxNetwork installation can take from an hour to three hours (not including the time to download).

CentOS version requirements

At the time of writing this document, only CentOS 6.3 is fully supported for IxVM – it is also important to note that performing an update (for i.e. `yum update`) will upgrade the version of CentOS to an unsupported version

Note: Running IxVM on a CentoS 5.6 KVM should still work, but there are some limitations that are caused by the version of this hypervisor. Ixia suggests you use a CentOS 6.3 KVM.

-- please do not run such commands when working with Ixia IxVM software.

In addition, make sure you ignore popup messages such as the following!

Figure 39-3.

The pop-up message

Topology

Use case 1 – Back to back test

The sphere in the following topology represents all virtualized components that are hosted by the Ixia application controller including the DHCP and NTP server.

Use case 2 – External connectivity

Building upon the previous use-case, this will focus on enabling port forwarding on the host, which will allow non-virtualized components such as IxTCL wish shell, IxNetwork and the Microsoft Remote Desktop client to remotely connect to the virtualized Windows VM without consuming CPU or memory resources on the host – this would considerably benefit customers that are conservative regarding host CPU/memory consumption by the Windows VM.

Use case 1 – Back to back test

Prerequisites

Ensure that you have the following:

Introduction to libvirt daemon

Ensure that the libvirtd is running:[root@localhost ~]# service libvirtd status

libvirtd (pid xxxx) is running...

If for some reason, the service/daemon is not running, manually start of the service:

[root@localhost ~]# service libvirtd start 
Starting libvirtd daemon:[OK] 

Establish the QEMU connection

Launch VMM (Virtual Machine Manager) from Applications -> Systems Tools -> Virtual Machine Manager.

Figure 39-4.

Virtual Machine Manager screen

Establish a connection to the QEMU/KVM hypervisor via File -> Add Connection -> Connect:

Figure 39-5.

The Add Connection screen

Note: Make sure the hypervisor is set to QEMU and not XEN. The default hypervisor for the GUI is XEN.

Figure 39-6.

The Virtual Machine Manager screen

Create Ethernet Bridge for Management network

On the main dialog of Virtual Machine Manager, click on the connection to localhost (ID: qemu) to highlight it and then navigate to: Edit -> Host Details -> Virtual Networks. Click on the default network to highlight it and ensure that it is Active and enabled for "Autostart on Boot":

VMM has utilized the Linux brctl command to setup and maintain an Ethernet bridge. The name of the device/network from libvirt's perspective is default and the Linux Ethernet bridge identifier is virbr0; to determine the status of this bridge you can simply run: `ifconfig virbr0` from the shell. The purpose of the bridge is to simply connect different multiple Ethernet capable virtual devices together just as a real layer-2 switch would operate. In the context of this particular use case, the bridge will serve as the management network that will interconnect the Windows VM and two IxVM ports.

VMM will also provide the DHCP start and end addresses as parameters to a process called dnsmasq, which is a lightweight DHCP server (among other capabilities) to provide DHCP addresses to all connected hosts on the default bridge, and for this use case this will translate to the Windows VM and the eth0 interface of the two IxVM ports.

For more information on libvirt networking:

Create Ethernet bridge for test ports

To establish a dedicated and isolated bridge between the IxVM ports, create a new virtual network (click on the button with the + icon):

Figure 39-7.

Create a new virtual network screen

Network Name: ixvm_bridge

Network: 0.0.0.0/24

DHCP Start/End range: 0.0.0.0

Physical network: Isolated virtual network

Ethernet Bridge: ixvm_bridge should now be running and DHCP (through dnsmasq) should NOT be providing out any addresses since the range is null:

Figure 39-8.

Host Details screen

Now, close VMM and create a new shell using Terminal (from Applications -> Accessories).

Note: This step assumes you have a separate file system mounted under /nobackup as defined in the first document. If you need to mount this directory, you must do so via `mkdir /nobackup` && `mount /dev/sda2 /nobackup`.

Create the following directories (if they do not already exist):

[root@localhost /]# cd /nobackup 
[root@localhost nobackup]# mkdir libvirt 
[root@localhost nobackup]# cd libvirt/ 
[root@localhost libvirt]# mkdir images 
[root@localhost libvirt]# cd images 
[root@localhost images]# pwd 
/nobackup/libvirt/images 

Download the latest KVM IxVM image into the above directory and ensure executable permissions for root:

[root@localhost images]# chmod u+x VM_IxVM_QemuKVM-
1.0.0.68.sh 

Instantiate IxVMPort1

Run the script to create instance for IxVM_Port1: 
[root@localhost images]# ./VM_IxVM_QemuKVM-1.0.0.68.sh 
Host System: CentOS 
Creating virtual machine 
Enter virtual machine(domain) name: IxVM_Port1 
 Setting up network configuration 
        NETWORKS_LIST 
default 
ixvm_bridge 
Enter management network name: default 
Enter test network name: ixvm_bridge 
Stopping libvirtd daemon: [  OK  ] 
Starting libvirtd daemon: [  OK  ] 
VIRTUAL MACHINE INFO 
Machine name: IxVM_Port1 
Management NIC: default 
Test NIC: ixvm_bridge 
######################################################## 
# [warn]: libvirt daemon has just been restarted in order 
that  # 
# new configuration to take effect; note that it may be # 
# needed to restart Virtual Machine Manager also        # 
######################################################## 

Note: The script has essentially created a new QEMU-KVM instance and connected the new VM's eth0 virtual interface to the default network and eth1 to the ixvm_bridge (created earlier). When the IxVM_Port1 starts, it will attempt to retrieve an IP address from the DHCP server through eth0 interface.

Instantiate IxVMPort2

Run the script again for IxVM_Port2: 
[root@localhost images]# ./VM_IxVM_QemuKVM-1.0.0.68.sh 
Host System: CentOS 
Creating virtual machine 
Enter virtual machine(domain) name: IxVM_Port2 
 Setting up network configuration 
NETWORKS_LIST 
default 
ixvm_bridge 
Enter management network name: default 
Enter test network name: ixvm_bridge 
Stopping libvirtd daemon: [  OK  ] 
Starting libvirtd daemon: [  OK  ] 
VIRTUAL MACHINE INFO 
Machine name: IxVM_Port2 
Management NIC: default 
Test NIC: ixvm_bridge 
######################################################## 
# [warn]: libvirt daemon has just been restarted in order 
that  # 
# new configuration to take effect; note that it may be # 
# needed to restart Virtual Machine Manager also        # 
######################################################## 

Note: This second VM is connected to the same default network and ixvm_bridge. The two VMs will be able to talk to each other and to the Windows VM via the default network; moreover, the two VMs will have a private and isolated connection to each other via the eth1 interfaces and ixvm_bridge.

Create and instantiate IxVM management VM

Go back to the VMM GUI, highlight the "qemu" connection and click on "New" to create a new VM instance:

Figure 39-9.

The VM instance screen

Note: The VM status for both instances is in the Shutoff state and while they are in this state they will not consume any host CPU cycles as it will need all available processing power to complete the following task of instantiating a Windows VM as fast as possible.

Name: IxVM

Virtualization method: Fully virtualized (CPU architecture: x86_x64)

Hypervisor: KVM

Installation method: Local installation media.

OS Type:Windows

OS Variant:Microsoft Windows XP (x86_64)

Installation media:<Select ISO or CD-ROM>

Storage:File (disk image)

Location:/nobackup/libvirt/images/IxVM.img

Size:60000 MB

Allocate:Uncheck (this option will allocate disk space on the fly as needed).

Network:Virtual Network -> Network: default.

Memory

Max memory:4000 MB

Startup mem.:1024 MB

Virtual CPUs:2

Click on "Finish" in the last dialog to create and launch the VM.

Install Windows 7

Once the VM has been successfully instantiated, follow and select the default options of installing Windows 7:

Pre-requisites:

Installation Steps:

  1. First, you need to choose your language and keyboard settings.
  2. Figure 39-10.

    Windows 7 Language and Keyboard

  3. The Install now window appears. Click Install now to proceed.
  4. The License Agreement window appears. Select the I accept the license terms check box and click OK.
  5. The Installation Type window appears where you need to select the type of installation you want to do. Select Custom (advanced) for a fresh install of Windows 7.
  6. Figure 39-11.

    Windows 7 Installation Type

  7. Next you need to choose the location in your disk where you want to install Windows 7.
  8. Figure 39-12.

    Windows 7 Installation Location

  9. The installation starts and after sometime you will be asked to provide your user name and computer name.
    You can provide the user name as IxVM User.
  10. Figure 39-13.

    Windows 7 User name

  11. Next you need to provide a password for your account.
  12. Figure 39-14.

    Windows 7 Password

Note: Leaving the password blank is optional but will provide an advantage as it will allow the Windows VM to login automatically without a blocking login prompt.

  1. You then need to configure the updates to Ask me later. Next configure your time zone and location.
    Windows 7 is now successfully installed on your virtual machine.

Customize Windows 7

To improve security, Windows 7 has the user account control option that is set by default to ask permission for specific operations (ex: running different executable files). To run IxVM properly, this option has to be disabled:

To change the settings, change the view in Control Panel to "Small icons" and go to "User Accounts".

  1. Click Start and then select Control Panel option.
  2. Click User Accounts option. The user control panel screen shows as follows:
  3. Figure 39-15.

    The user control panel screen

Go to "Change User Account Control Settings" and drag the dial down to "Never notify". The screen shows the options as follows:

Figure 39-16.

The user control panel screen

You need to restart Windows for the changes to take place. Please do this before continuing with the rest of the changes.

By default, Windows will display alerts relating to the status of the Firewall, Windows Automatic Updates and Virus Protection. Since none of these services are required, disable the alerts:

  1. Click Start and then select Control Panel option.
  2. Click Notification Area icons.
  3. Figure 39-17.

    The user control panel screen

Now change the Action center behavior to "Hide icon and notifications" and press OK.

Figure 39-18.

The user control panel screen

Ensure the Windows Firewall is disabled (since it will interfere with IxVM management traffic):

  1. Click Start and then select Windows Firewall option.
  2. Turn Windows Firewall on or off.
  3. Figure 39-19.

    The Customize settings of each network type screen

The "Sleep" and "Turn off display" options need to be disabled also:

  1. Click Start and then select Control Panel option.
  2. Click Power options and then select Change plan settings option.
  3. Figure 39-20.

    The Change plan settings screen

In the same window as above, go to "Change advanced power settings" and under Hard Disk option Turn off hard disk after Setting enter 0 (zero) to set to Never. When done, click OK and Save changes to finish with setting up the power options.

Figure 39-21.

The Power Options screen

Next, disable the automatic updates:

  1. Click Start and then select Control Panel option.
  2. In the windows updates and in the left side of the screen click on the Change settings.
  3. Set the Important updates option to Never check for updates.
  4. Figure 39-22.

    The Never check for updates screen

In case you intend to use Deployment Wizard to install or upgrade a virtual chassis on this Windows machine you need to disable Simple file sharing or Sharing wizard:

  1. In the Windows Explorer options click Tools.
  2. Click View tab under Folder Options.
  3. Scroll down to the bottom where you will find "Use Sharing Wizard".
  4. Clear the option.

Figure 39-23.

The View Tab screen

Finally to login remotely to this Windows 7 machine, you need to enable the remote desktop option:

  1. Click start and right click on My Computer.
  2. In the left side of the Window select Remote settings.
  3. Select the second option from the radio button options as shown in the below screen shot:

Figure 39-24.

The Remote Tab screen

IxVM Live CD Installation

The IxVM liveCD image can be installed in a virtual machine created on any of the supported Hypervisor / Host OS on page 39-3.
Here is a step by step guide to deploy a liveCD image on a virtual machine, using VMware 5.0:

  1. Copy the .iso file for the live CD to the hypervisor datastore.
  2. On the File menu, click New, and then click Virtual Machine (Ctrl+N hotkey). The Configuration window appears as shown below.

  3. Select the type of configuration you want for the virtual machine, and then click Next. The Name and Location window appears.

  4. Type the name of the new virtual machine, and then click Next. The Storage window appears.

  5. Select the destination storage for the virtual machine files, and then click Next. The Guest Operating System window appears.

  6. Select the Red Hat Enterprise Linux 6 (32-bit) guest operating system, and then click Next. The Network window appears.

  7. Specify the network connections that will be used with the virtual machine, and then click Next. The Create a Disk window appears.

  8. Create the disk for the virtual machine by specifying the disk size and provisioning policy, and then click Next. The Ready to Complete window appears.

  9. Click Continue. The Virtual Machine Properties window appears.
    Note: Select the Edit the virtual machine settings before completion check box before clicking Continue.
  10. In the Virtual Machine Propeties window, select CPUs from the list of Hardware on the left. Add 2 CPU cores and 2 GB of memory to the VM.

  11. Next select New CD/DVD and define the following properties:
  12. Under Device Status, select the Connect at power on check box.
  13. Under Device Type, click Datastore ISO File.
  14. Click Browse, and then select the live CD .iso file from the local datastore

    .
  15. Click Finish and localize the VM in the hypervisor inventory.
  16. Power on the virtual machine. The following boot screen appears.

  17. After the booting is done, the setup utility tool appears as shown below.

  18. Navigate to the Quit button by clicking Tab. The CentOS login screen appears, where you have to log in with the root user (no password required).

Note:
  • The LiveCD can only be used in the supported virtualized environments (VMware, KVM, ESX).
  • The LiveCD cannot be used on physical machines due to the custom Ixia kernel.
  • The LiveCD can be used only if there is at most one hard disk configured on the virtual machine (it also works with no hard disk configured).

Install IxOS and IxNetwork

From the Windows VM instance, download and install IxOS 6.60 EA and IxNetwork 7.20 EA Patch1 (respectively). You will be asked to reboot after the IxOS installation and once more after the IxNetwork 7.20 EA Patch1 installation. In addition, please ensure that that the appropriate IxVM/IxNetwork licenses are also installed.

Note: When installing IxOS, make sure Client, IxVMServer and Tcl Server are selected to be installed. In the "Custom setup" dialog, you will be given a choice over Demo Server or IxVM Server. Select IxVM Server.

Install and configure NTP server on the host

For this use case, we will be using the Linux host as the NTP server. To do this, the NTP package should be installed:

[root@localhost ~]# yum install ntp 
[root@localhost ~]# service ntpd start 
Starting ntpd:[ OK ] 

To allow the host to serve NTP requests, modify /etc/ntp.conf and append the following line:

restrict 192.168.122.0 mask 255.255.255.0 nomodify notrap 

Note: 192.168.122/24 is the default network for libvirt and since we have used the default network for the management bridge, the entry for /etc/ntp.conf should match.

Allow the NTP service to run at boot-time and manually restart the service for the new modifications to take affect:

[root@localhost ~]# chkconfig ntpd on 
[root@localhost ~]# service ntpd restart 
Shutting down ntpd:[ OK ] 
Starting ntpd:[ OK ] 

Configuring DHCP Server

The DHCP server is required for a faster way to deploy IxVM Cards and attach them to Virtual Chassis in an environment that is isolated from any automatic IP address policy. This server provides IP addresses based on default configuration, and also has an interface that can be used as a tool to customize the DHCP Server.

IxVM server needs to include DHCP server for accelerating card deployment in private management networks.

Note: Open DHCP Server used by IxVM server only listens on Static Interfaces that means the IP address is fixed and not obtained from another DHCP Server. Any dynamic interfaces specified are ignored.

You can configure the DHCP server through the DHCP Configuration dialog box that can be found in IxServer DHCP Configuration under under Tools. This option is unavailable if you have not installed the IxVM component for IxServer. This command starts a standalone application that configures the DHCP server.

The following image shows the IxDHCPConfig dialog box:

Figure 39-25.

The IxDHCPConfig dialog box

General Tab:

Dynamic Address Allocation tab:

The following image shows the Dynamic Address Allocation tab:

Figure 39-26.

The Dynamic Address Allocation tab

Static Address Allocation tab:

The following image shows the Static Address Allocation tab:

Figure 39-27.

The Static Address Allocation tab

Advanced Tab:

In its default state this tab is blank and needs to be configured with care as the changes here have a global effect. More detailed information on all available commands refer to List of DHCP Options.

The following image shows the Advanced tab:

Figure 39-28.

The Advanced tab

DHCP Server customization in Deployment Wizard

Deployment Wizard shows DHCP Server customization on both Install and Upgrade flows.

The available options are to Enable or Disable DHCP Server on IxServer.

Deployment Wizard shows the same DHCP Server properties as in IxServer -Dynamic Address Allocation tab.

Deployment Wizard provides the following options:

The following image shows the DHCP server options dialog box under IxVM Deployment wizard:

Figure 39-29.

The DHCP server option

IxOS Topology Transfer

The IxServer.ixs file contains all the information about card and port map, chassis type, card types, stream configurations, and port properties. Using this feature, the IxServer.ixs file gets copied from an older IxOS installation folder to the newly installed IxOS folder. You can copy this file by using various methods as follows:

Use Deployment Wizard to select the required topology from the available IxOS versions to transfer

This option is available when using Deployment Wizard to upgrade an already existing chassis.

In the Install Files page under Windows Virtual Controller, all the IxOS versions that are detected on the chassis are shown in the right side pane.

You can select any of the available versions to have its IxServer.ixs file copied to the installation folder of the new IxOS version.

Note: All the available versions are shown, which include the uninstalled versions as well. If a version does not have the .ixs file available, it does not appear in the pane.

Use the IxOSTransferTopology importer application that is automatically run at the end of any new IxOS installation

In this option, the topology configuration file is copied from the latest installed IxOS version. All installed IxOS versions are sorted and the latest version is picked up.

Note: If the application cannot find the latest installed version, this option is unavailable.

In this option, the topology configuration file is copied from the most recently run IxOS version. The latest version is taken from the registry.

Note: If the application cannot find the last run version or the last run version does not have a valid .ixs file, this option is unavailable.

When you select this option, the Select version page appears. This page contains all the available versions, from which you can select one version (only the valid versions appear).

Click Next again. The configuration file is imported from the selected version. After the import configuration is done, the Finish page appears.

You need to manually identify the source folder, from where you want to copy the file. This can be a backup folder for older IxOS versions, but you need to have only one .ixs file in each sub-folder.

Select the folder from where the topology needs to be copied. You can copy the topology either from installed or uninstalled versions that have a valid .ixs configuration file.

If you select this option, the installer skips the topology transfer step. No topology file is transferred and a new empty topology file is created at the first IxServer start.

Note: If you want to manually run the IxOSTransferTopology tool between various IxOS installations, you can find it at the following location:

C:\Program Files\Ixia\IxAdmin\bin\ IxOSTransferTopology.exe

Instantiate IxVM test ports

Now that the Windows VM has been successfully established, it's time to bring up the IxVM ports. In the Virtual Machine Manager main GUI, right click on IxVM_Port1 and click on Run (do the same for IxVM_Port2). This will take about 2-5 minutes for the ports to boot up, initialize and obtain an IP address from DHCP.

Figure 39-30.

The VM Manager screen

Double-click on IxVM_Port1 (for console); login as root and make a note of the IP address for eth0 (do the same for IxVM_Port2):

Figure 39-31.

The console window

Note: At the time of writing, the password for root is ixia123.

Go back into VMM, double-click on the Windows VM and navigate to IxServer -> Tools -> Options. Once you are in the IxServer Options menu, set the NTP Master Server to 192.168.122.1 (the host):

Figure 39-32.

The IxServer screen

For the changes to take affect; restart IxServer, launch IxExplorer (by connecting to the localhost). Stop the firewall:

[root@localhost ~]# /etc/init.d/iptables stop 
Flushing firewall rules: [  OK  ] 
Setting chains to policy ACCEPT: filter [  OK  ] 
Unloading iptables modules: [  OK  ] 
[root@localhost ~]# 

Right click on the chassis (should be in a green state) and click on "Add Ports to Chassis":

Figure 39-33.

The screen showing Add Ports to Chassis option

The initial virtual ports dialog contains a default IxVM card/port; delete this by highlighting it and clicking on the following button:

Figure 39-34.

The Chassis properties screen

Then add your new cards, apply and OK:

Figure 39-35.

The Chassis properties screen showing the ass new card option

A successful IxVM connection should appear as the following:

Figure 39-36. The successful IxVM connection screen

Launch IxNetwork 7.0, use the localhost as the chassis, and add both IxVM ports.

Figure 39-37.

The Port Selection screen

Create a back-to-back configuration by adding IPv4/IPv6 protocol interfaces on each port and send some test traffic through at low-rates (for e.g. 100 pps) to verify traffic:

Figure 39-38.

The data plane port statistics screen

To look at the raw counters (vnet2 maps to -> IxVM_Port1:eth1 and vnet4 -> IxVM_Port2:et1),

[root@localhost ~]# ifconfig vnet2 
vnet2     Link encap:Ethernet  HWaddr FE:16:3E:58:F0:42 
UP BROADCAST RUNNING MULTICAST  MTU:1500  Metric:1 
RX packets:1561980 errors:0 dropped:0 overruns:0 frame:0 
TX packets:1558030 errors:0 dropped:0 overruns:635040 
carrier:0 
collisions:0 txqueuelen:500 
RX bytes:93718728 (89.3 MiB)  TX bytes:92541680 (88.2 
MiB) 
[root@localhost ~]# ifconfig vnet4 
vnet4     Link encap:Ethernet  HWaddr FE:16:3E:58:74:0E 
UP BROADCAST RUNNING MULTICAST  MTU:1500  Metric:1 
RX packets:1882045 errors:0 dropped:0 overruns:0 frame:0 
TX packets:1352794 errors:0 dropped:0 overruns:513842 
carrier:0 
collisions:0 txqueuelen:500 
RX bytes:112922556 (107.6 MiB)  TX bytes:80227696 (76.5 
MiB) 
[root@localhost ~]# 

Use case 2 – External connectivity

Prerequisites

Ensure that you have the following:

Introduction to xinet.d

In the open source Linux world, xinetd, the eXtended InterNET Daemon is a process-daemon that provides services such as access control, logging, cron services, and port forwarding. Since this service is a fast, secure and efficient means of forwarding traffic from the Windows VM to the external client, xinetd will suffice.

Discover the Windows VM IP

From the VMM GUI, navigate to the Windows VM console, enter the command prompt (Start -> Run -> cmd) and make a note of the IPv4 address that it is assigned (in the following case, the address is 192.168.122.149):

Figure 39-39.

The command prompt window

Enable remote desktop for IxVM User

Goto System Properties (from Start -> Run -> right click on "My Computer"), navigate to the "Remote" tab and enable "Allow users to connect remotely to this computer".

Figure 39-40.

The Remote Tab screen

Click on "Select Remote Users..." and add IxVM User:

Figure 39-41.

The Remote Desktop Users screen

Install xinetd on the host

[root@localhost init.d]# yum install xinetd 
... 
Installed: 
  xinetd.x86_64 2:2.3.14-13.el5 
Configure common Ixia TCP ports as xinetd services 

On the host, edit the /etc/services file and at the end of file (under "# Local services") add the following three entries:

ixostcl		4555/tcp		# IxOS TCL server. 
ixnetclient		6809/tcp		# IxNetwork server. 
ixnettcl		8009/tcp		# IxNetwork TCL server. 

Create port-forwarding definition file for xinetd

Create a file called ixia in the /etc/xinetd.d directory with the following contents (making a note of 192.168.122.149 as the destination for all services):

service ixostcl 
{ flags = REUSE 
     socket_type = stream 
     wait = no 
     user = root 
     server = /usr/bin/nc 
     server_args = 192.168.122.149 4555 
     log_on_failure += USERID 
} 
service ixnetclient 
{ 
     flags = REUSE 
     socket_type = stream 
     wait = no 
     user = root 
     server = /usr/bin/nc 
     server_args = 192.168.122.149 6809 
     log_on_failure += USERID 
} 
service ixnettcl 
{ 
     flags = REUSE 
     socket_type = stream 
     wait = no 
     user = root 
     server = /usr/bin/nc 
     server_args = 192.168.122.149 8009 
     log_on_failure += USERID 
} 
service ms-wbt-server 
{ 
     flags = REUSE 
     socket_type = stream 
     wait = no 
     user = root 
     server = /usr/bin/nc 
     server_args = 192.168.122.149 3389 
     log_on_failure += USERID 
} 

Save and exit the editor, ensure executable permissions for the ixia file, allow xinetd to be automatically restarted on boot-up and manually start the xinet.d service:

[root@localhost init.d]# chmod +x ixia 
[root@localhost init.d]# chkconfig xinetd on 
[root@localhost init.d]# service xinetd start 
Starting xinetd: [  OK  ] 

Test Microsoft Remote Desktop connection

From your laptop client, connect to your server, for example:

Figure 39-42.

Remote Desktop connection screen

Test IxNetwork TCL server

From your laptop client, connect to your server, for example:

Figure 39-43.

The console window

Xen Server Hypervisor Support

The Xen Server installation is very similar to the KVM one.

Hardware requirements

This document focuses on the Ixia Application controller (also known as "AppServer") and the time of writing, this is a single-processor Intel Xeon (quad core), 24GB of DDR2 RAM, two integrated GbE LAN ports, and one slim VDROM drive.

After installing CentOS 5.6 x64 on the physical machine, install the xen kernel and depending packages (yum install xen virt-manager kernel-xen) and set xend to start at boot (chkconfig xend on ). After this, reboo the machine. To check that the host has booted into the xen kernel, use the command „uname -a | grep xen". If the command returns an output, then the Xen hypervisor can be used.

Xen already provides a bridge that can be used for the management interface (xenbr) and by connecting the virtual machines to this bridge, you should have access to your local management network and DHCP server.

Create an IxVM machine

Run the Xen script to create a virtual machine with all the IxVM components installed already:

	[root@localhost images]# ./VM_IxVM_XEN-2.0.0.228.sh 
	Host System: CentOS 
	Creating virtual machine 
	Enter virtual machine(domain) name: IxVM_Port1 
	Setting up network configuration 
		NETWORKS_LIST 
	xenbr0 
	default 
	ixvm_bridge 
	Enter management network name: xenbr0 
	Enter test network name: ixvm_bridge 
	Stopping libvirtd daemon: [ OK ] 
	Starting libvirtd daemon: [ OK ] 
	VIRTUAL MACHINE INFO 
	Machine name: IxVM_Port1 
	Management NIC: xenbr0 
	Test NIC: ixvm_bridge 
 
 
 
	######################################################## 
	# [warn]: libvirt daemon has just been restarted in order 
that #
	# new configuration to take effect; note that it may be #
	# needed to restart Virtual Machine Manager also # 
	########################################################

Note: Before powering on the virtual machine, make sure that SELinux is not enabled on the host operating system. Edit the /etc/selinux/conf file and check that the SELINUX= option is set to „disabled". Reboot the host machine after this change.

Create and instantiate IxVM management VM

Go back to the VMM GUI, highlight the qemu connection and click on "New" to create a new VM instance:

Figure 39-44.

The VM instance screen

Note: The VM status for both instances is in the Shutoff state and while they are in this state they will not consume any host CPU cycles as it will need all available processing power to complete the following task of instantiating a Windows VM as fast as possible.

Name: IxVM

Virtualization method: Fully virtualized (CPU architecture: x86_x64)

Hypervisor: KVM

Installation method: Local installation media.

OS Type:Windows

OS Variant:Microsoft Windows XP (x86_64)

Installation media:<Select ISO or CD-ROM>

Storage:File (disk image)

Location:/nobackup/libvirt/images/IxVM.img

Size:60000 MB

Allocate:Uncheck (this option will allocate disk space on the fly as needed).

Network:Virtual Network -> Network: default.

Memory

Max memory:4000 MB

Startup mem.:1024 MB

Virtual CPUs:2

Click on "Finish" in the last dialog to create and launch the VM.

****For easy deployment of large setups on the open source Xen Server, Discovery Server, and Chassis Builder, the Deployment Wizard includes support for the Xen Hypervisor.

Discovery Server supports discovering Virtual Load Modules from XenServer by using the following option:

Chassis Builder supports managing appliances from Xen Server when rebuilding the chassis topology. It also offers support for restarting the Virtual Load Modules created on a Xen Server.

Deployment Wizard supports deploying or updating Virtual Load Modules on Xen Server. It has the following functionalities:

Xen support in Chassis Builder

When machines are discovered with discovery server and shown in chassis builder, the new type Xen is shown on the type column as shown in the following image:

Figure 39-45.

The Type column showing the Xen details

In addition, when a new Xen virtual machine is added in the chassis topology, the type of the VM can be seen in the following VM information:

Figure 39-46.

The chassis topology details

We can also restart the Xen virtual machine in a similar way as Qemu, KVM, and VmWare types of machine are restarted.

Right-click the machine name, and then click Reboot from the shortcut menu. The following image shows the Reboot option:

Figure 39-47.

The Reboot option

Set the credentials for the host of the virtual machine, as shown in the following image:

Figure 39-48.

The Set Credentials window

The Restart process gets started.

Bare-metal (RPM) Installation

The sequence for a bare-metal installation of IxVM with RPMs is as follows:

  1. Download one of the supported Linux OSes, and install it on your bare metal server.
  2. Download the IxVM RPMs, and install them on the bare metal server.
  3. Install IxServer, Discovery Server, and IxAdmin on a Windows computer.

The following sections describe each of these steps.

After you have completed the steps, you can begin using the virtual Ixia ports with your Ixia testing application.

Installing Linux

Download one of the supported Linux distributions, and install it on your bare metal server. See Requirements (see "Requirements" on page 2) or the release notes for the list of supported Linux distributions.

For whichever distribution you choose, you must use the default (unpatched) kernel.

Installing IxVM Server, IxExplorer, and IxNetwork

For a bare-metal Linux deployment, you install IxServer, IxExplorer, IxNetwork, Discovery Server, and Deployment Wizard on a 32-bit Windows 7 computer that can access the bare-metal server.

All components can be downloaded from Ixia's website.

To install IxVM Server, IxExplorer, IxNetwork, Discovery Server, and IxAdmin:

  1. Download the IxVM IxOS installer, and install IxOS on the Windows computer. Make sure that you select the following two components:
    • IxServer
    • Client
  2. Download the IxNetwork installer, and install IxNetwork on the Windows computer. Select all the components, including the one marked IxVM Server (an IxNetwork-specific component required for IxVM, not to be confused with the IxOS IxVM Server component).
  3. Download and install Ixia Discovery Server on the Windows computer.
  4. Download and install IxAdmin Client on the Windows computer.

Installing the IxVM RPM Packages

Three IxVM components must be installed on the bare metal server:

All three components are supplied as RPM packages compiled for the supported Linux distributions.

To install the IxVM RPM packages:

  1. Log on to the bare-metal server under an account with admin privileges.
  2. Download the IxVM RPM packages appropriate for the Linux distribution installed on the bare metal server.
  3. Type the following to install the IxOS-VM package:
  4. rpm –i <ixvm>.rpm

    where <ixvm> is the name of the IxOS-VM RPM package.

  5. Type the following to install the IxNetwork-VM package:
  6. rpm –i <ixnetwork>.rpm

    where <ixnetwork> is the name of the IxNetwork-VM RPM package.

  7. Type the following to install the IxAdminAgent-VM package:
  8. rpm –i <ixadminagent>.rpm

    where <ixadminagent> is the name of the IxAdminAgent-VM RPM package.

  9. Start the software agent using either of the following methods:
    • Reboot the machine
    • Enter: /etc/init.d/ixvm start
  10. Enter ps -e to verify that bin/InterfaceManager is running.
  11. After installation, if you need to find the build numbers of the RPMs that are installed, you can use the following commands:
    • IxOS-VM: rpm –qa ixvm
    • IxNetwork-VM: rpm –qa ixnetwork_ixvm
    • IxAdminAgent-VM: rpm –qa ixadminagent

Note: The Ixia Kernel rpm install is only for advanced users and should not be used in Bare-Metal scenarios.

Configuring NTP

If you are using IxVM ports from different instances of IxVM Server, or you are using a combination of IxVM ports and Ixia hardware ports, you must configure a common NTP time source so that traffic can be synchronized among the ports.

The NTP time source must be configured in IxVM server (for IxVM ports) and in IxOS server (for hardware ports).

To configure an NTP time source:

  1. Open IxVM Server or IxServer.
  2. On the menu bar, click TOOLS| OPTIONS | DIALOG.
  3. In the NTP MASTER SERVER field, specify the NTP server.
  4. Click OK.
  5. Figure 39-49.

    The Dialog tab under IxServer Options

NTP server options for IxVM cards

The IxVM-enabled version of IxServer supports a number of options for using an NTP time server. To configure NTP for IxVM:

  1. Display the copy of IxServer running on the IxVM Windows controller host.
  2. Click TOOLS| OPTIONS | DIALOG.
  3. In the NTP Master Server field, enter one of the following:
    • IP address of an NTP server that is reachable by the IxVM cards
    • Hostname of an NTP server (the host name must be resolvable by DNS and reachable by the IxVM cards)
    • 0, to disable the IxVM cards from sourcing NTP through Ixia applications. If you use this option, you must supply a time source to the IxVM cards by some other means.

Single-port vs. Multi-port Cards

There are two types of IxVM virtual load modules: single-port and multi-port.

All IxVM virtual load modules require one interface for management traffic, and at least one interface to generate test traffic.

Some test traffic and routing protocols are only supported on single-port cards, while others are supported on either type.

One virtual chassis can control up to 32 virtual cards.

Note: The IxVM test ports can also be TAP interfaces created on the Virtual Machines.

Converting Single-port cards into Multi-port cards

You can convert a single-port card into a multi-port card, or add ports to an existing multi-port card. There are three tasks required for this process:

  1. For each test port that you want to add, create an additional test network.
  2. Add the additional test ports to the VM card.
  3. In the test application (IxExplorer, IxNetwork, or IxLoad), add or discover the ports added to the card.

Step 1. Create the Additional Test Networks

If you are adding ports to a multi-port card, each port should have its own network in vSphere. Use the procedure below to create an additional test network.

To create an additional test network in vSphere:

  1. Login to vSphere client.
  2. Select the ESX(i) host.
  3. Click the CONFIGURATION tab.
  4. In the Hardware area, click NETWORKING.
  5. Click ADD NETWORKING (upper right).
  6. The Add Network Wizard displays, with the Connection Type set to Virtual Machine.

  7. Click NEXT.
  8. The Network Access pane displays.

  9. Select CREATE A VIRTUAL SWITCH, then click NEXT.
  10. In the NETWORK LABEL field, enter a label for the additional test network, then click NEXT, then click FINISH.

Step 2. Add Ports to the Card

To add ports to an IxVM card, use the procedure below.

To add ports to an IxVM card:

  1. Login to vSphere client.
  2. Select the VM you want to add ports to.
  3. SHUT DOWN or POWER OFF the VM.
  4. Select the VM, and then click EDIT VIRTUAL MACHINE on the Getting Started tab.
  5. The Virtual Machine Properties window displays.

  6. On the Hardware tab, click ADD.
  7. The Add Hardware wizard displays, with the Device Type pane selected.

  8. Select Ethernet Adapter, then click NEXT.
  9. The Network Connection pane displays.

  10. In the Adapter Type field, select VMXNET3.
  11. In the Network Label field, select the destination test network, then click NEXT, then click FINISH.
  12. Repeat steps 4-8 for any additional ports you want to add.
  13. Click OK to close the window.
  14. Power on the VM.

Step 3. (IxExplorer): Adding a Multi-port Card

In IxExplorer, after adding ports to a card, you must manually add (or re-add) a card to the card list.

To manually add a multi-port card to an IxVM chassis:

  1. In vSphere client, select the chassis, click CONSOLE, and login to Windows.
  2. Start IxExplorer.
  3. Right-click the chassis, and then select PROPERTIES.
  4. Select VIRTUAL PORTS.
  5. If the card you added ports to is already in the card list, select the card, and remove it.
  6. Click the MULTI-ADD CARD (the +++Card) button.
  7. IxExplorer adds the card as a multi-port card (the SINGLE-NIC checkbox is not checked).

  8. Select the card, then click ADD PORT. Repeat for each additional port you are want to add.
  9. Click OK.
  10. In the chassis/card/port list, the card should now display multiple ports.

Step 4. (IxNetwork): Discovering a Multi-port Card

In IxNetwork, after adding ports to a card, you use Discovery Server to automatically add the card and its ports to the chassis/card/port list.

To discover a card in IxNetwork:

  1. After you have added ethernet adapters to the VM, you must rebuild the chassis in IxNetwork, in order for Discovery Server to discover them.
  2. In vSphere client, select the chassis, click CONSOLE, and login to Windows.
  3. Start IxNetwork.
  4. Select TEST CONFIGURATION.
  5. Select PORT MANAGER.
  6. Click ADD PORTS.
  7. If the chassis is in the chassis list, select it. If the chassis is not in the list, add it.
  8. The Add Virtual Chassis window displays.

  9. Make sure the PERFORM AUTOMATIC DISCOVERY is checked, then click AUTOMATIC.

IxNetwork triggers Discovery Server to discover IxVM cards. After the discovery process is complete, the card should now display multiple ports in the chassis/card/port list.

Sample Configuration

This section describes the steps in creating a sample IxVM configuration. You can use the steps in this section as a guide in creating your own configuration.

Step 1. Install vSphere

If you have not already installed vSphere, follow the procedure for installing vSphere.

For details see Downloading and Installing vSphere on page 39-15.

Configuration Details

By default, VMware creates one virtual switch, vSwitch0, which is used to access the ESX(i) server over the corporate LAN. VMware applies the name VM Network to the network served by vSwitch0. In the IxVM Windows VM in this example, this network is labeled Corporate Network.

Step 1. Configure the Source and Destination Networks

In vSphere, create two virtual switches (vSwitches): one to serve the network that carries the IxVM card management traffic, and one for the network that carries the test traffic. In vSphere, these are named source and destination networks.

For details see Creating the Source and Destination Networks on page 39-16.

Configuration Details

Name the networks as follows:

Step 3. Deploy a Windows VM

In vSphere, create a Windows VM with two NICs. Refer to the IxOS release notes for the list of Windows versions that IxVM supports.

Configuration Details

Step 4. Deploy the Linux OVA Template

Deploy two Linux VMs based on the Ixia kernel OVA.

For details see Deploying the IxVM Appliances (OVAs) on page 39-17.

Configuration Details

Step 5. Configure the IxVM card (Linux OVA) Addresses

If you configured the IxVM cards (Card01, Card02, Linux OVAs) to use DHCP addressing, skip this step.

If you configured the IxVM cards to use static addressing, configure their addresses.

For details see Configuring Static Addressing on page 39-18.

Configuration Details

Use the console to test connectivity by pinging card02 from card01 (or vice-versa).

Step 6. Configure the IxVM Chassis Addresses

Configure the IxVM chassis controller (the Windows VM), and start IxVM and the supporting services on it.

  1. Login to the Windows VM, and go through the procedure to license Windows.
  2. Download and install the following components on the IxVM chassis controller.
    • IxVM Server
    • Discovery Server
  3. Rename the two local area connections as follows:
    • Local Area Connection 1: VM network
    • Local Area Connection 2: IxVM Management Network
  4. If you configured the IxVM chassis controller to use static addressing, configure its addresses as follows:
  5. VM network: 10.200.27.250/24 (Default gateway: 10.200.27.1)

    IxVM Management Network = 10.0.0.250/24 (Default gateway: none)

Step 7. Discover the IxVM Cards

Start the Windows services, and discover the IxVM cards:

  1. Start IxServer.
  2. Start Discovery Server.
  3. In Discovery Server, uncheck CORPORATE NETWORK (10.200.x.x, there are no VMs on this network).
  4. Click SERVER | START BROADCAST to start Broadcast Discovery.
  5. Click the AUTODISCOVERY tab. This tab should indicate that two endpoints (the IxVM cards) have been discovered.
  6. Close the Discovery Server window.
  7. The Discovery Server minimizes and continues to run.

    The IxVM cards are ready for use. Start IxExplorer, IxNetwork, or IxLoad and add them to your list of ports.

What to do Next

After you have installed IxVM, you can begin using it. There are two things you need to do to use IxVM with an Ixia testing application:

Supported Protocols

To confirm that IxVM supports the protocols you want to use in a test, check the list of supported protocols in the the test application's user guide.

Finding and Adding IxVM Load Modules

To find and add IxVM load modules, use the Discovery Server. Directions for using Discovery Server are included in the test application's user guide.

Deployment Wizard

As IxVM continues to be adopted by more users, software based test assets will keep on multiplying. The user will take considerable time to deploy large scale systems manually. This could be error prone when port counts reach thousands.

The IxVM Deployment Wizard allows for mass deployment of IxVM software test assets into large scale test environments. It also automates the upgrade of an existing mass deployment to a new version of the software. This facilitates the deployment and upgrade of Windows Virtual Controllers and Virtual Load Modules.You can perform the following actions by using Deployment Wizard:

Upgrade Virtual Chassis

You can upgrade an existing virtual chassis using the Deployment Wizard.To upgrade an existing chassis, do the following:

  1. Open the Deployment Wizard.
  2. In the Start Wizard, click Upgrade Virtual Chassis.
  3. Click Next. The Chassis Info window appears.
  4. In the Hostname/IPbox, type the IP address of the virtual chassis.

Note: You can select the IP address by clicking Previously used. The IP addresses of the chassis that were previously used appears. You can select the IP address of the chassis that you want to upgrade.

Click Next. The Source Files dialog box appears.

Click to select the path of each Ixia software installed on the Windows Virtual Controller computer.

Select each Ixia software you want to uninstall.

You can select the following source files:

Upgrade the load modules by performing the following actions:

Upgrade Appliances

The Upgrade Appliances window shows a list of virtual load modules that you want to update.The following table describes the properties of the virtual load modules:
Field/Control
Description
State

If the virtual load module is available, the check box is selected. In this case, the virtual load module is not assigned to another virtual chassis.

Type

Shows the type of appliance, for example, PC, Qemu,or Vmware.

Appliance

Shows the name of the virtual load module that you want to update.

IP Address

Shows the IP address of the virtual load module.

Info

Shows the list of installed Ixia software on the virtual load module.

NICs No

Shows the number of virtual interfaces that are defined for each virtual load module.

Select Source Files

The Select Source Files window allows you to select the source files to upgrade an existing VM quest OS or IxNetwork to the new version of Ixia software.

  1. Click to select the source files needed to upgrade the installed Ixia software (.rpm, .zip).

You can select the following source files:

Install New Virtual Chassis

You can install a new virtual chassis using the Deployment Wizard.To install a new chassis, do the following:

Xen support in Deployment Wizard

Deployment Wizard offers support for deploying Virtual Load Modules on a Xen host.

The following image shows the Host Type in Deployment Wizard:

Figure 39-50.

The Host Type in Deployment Wizard

After testing Xen Host connection with the given credentials, on the next page the Host Settings window shows as follows:

Figure 39-51.

The Host Settings window

  1. Type the No. of Virtual Load Modules to be created.
  2. Type the Virtual Load Module Name.
  3. Select the Host Datastore.
  4. Select the virtual bridges for IxVM Card Management Network and IxVM Test Network.

The self-extracting image (.sh file) used for Virtual Load Module deployed on Xen is different from the Qemu/KVM .sh file (the .sh file name contains the hypervisor name).

The summary page shows the options selected by you on the Install new Virtual Load Module workflow as shown in the following figure:

Figure 39-52.

The Virtual Load Module workflow

To deploy a virtual load module manually on a Xen hypervisor you can use the following example:

[root@10-205-15-55 OVAs]# chmod +x VM_IxVM_XEN-2.0.0.218.sh

[root@10-205-15-55 OVAs]# ./VM_IxVM_XEN-2.0.0.218.sh

Configure Windows Virtual Controller Settings

You can configure the settings for Windows Virtual Controller.To configure the settings, do the following:

  1. Open the Deployment Wizard.
  2. In the Start Wizard window, click Install New Virtual Chassis and Virtual Load Modules.
  3. Click Next. The Chassis Info window appears.
  4. Enter the host details for the existing Windows Virtual Machine or Windows computer. For more information, see Configure Host Details.
  5. Click Next. The Source Files window appears.
  6. Click to select the source files needed to install a Virtual Controller on an existing OS.

You can select the following source files:

The following table describes the host details that you need to enter for an existing Windows Virtual Machine or Windows computer:
Field/Control
Description
Host Info
Click Previously used to select the IP address. The IP addresses of the chassis that were previously installed appears. You can select the IP address of the chassis that you want to install.
IP/Name
Type the IP address of the existing Windows computer where you want to install the virtual chassis.
User Name
Type the name of the existing Windows computer.
Password
Type the password of the existing Windows computer.
Domain
Select the check box next to the Domain box to make it available. You can enter the domain name of the existing Windows computer.
Test Connection
Click Test Connection to validate the input credentials.

Configure Virtual Load Module Settings

You can configure the settings for the characteristics of the Virtual Load Module you create. The characteristics include hypervisor type, virtual machine name, number of virtual machines, datastore and virtual network interfaces assignments.To configure the settings, do the following:

  1. Open the Deployment Wizard.
  2. Configure the Windows Virtual Controller settings. For more information, see Configure Windows Virtual Controller Settings.
  3. Click Host Type. The Host Type window appears.
  4. Enter the host details for the Virtual Load Module. For more information, see Configure Host Details.
  5. Click Next. The Host Settings window appears.
  6. Configure the host settings. For more information, see Configure Host Settings.
  7. Click Next. The Source Files window appears.
  8. Click to select the source files needed to install a new guest OS (.ova, .sh).
  9. Click Start to run the upgrade or installation process.

Configure Host Details

The following table describes the host details for the Virtual Load module:
Field/Control
Description
Select Virtual Load Modules Host Server
Click the relevant host OS information: Options include the following:
  • Sphere
  • QEMU
  • Bare-Metal
Find Previous
Click to find the information of hosts that you have used previously. Selecting a host from the list automatically shows the following host information:
  • IP/Name
  • User Name
  • Password
IP/Name
Type the IP address of the host server.
User Name
Click to find the host network.
Password
Type the password of the host server.
Domain
Select the check box to include the domain to which the host server belongs.
Test Connection
Click Test Connection to validate the input credentials.

Configure Host Settings

The following table describes the host settings that you need to configure for the Virtual Load Module:
Field/Control
Description
Guest Machine Name
Enter the desired name for the guest machines based on which it will automatically increment for new installation selections.
Note: The name of the guest machine will be followed by an incremental number from 1 to the Number of Guests per Host.
Number of Guests per Host
Enter the numbers of guests you need to create on the host. The maximum number of guests per host is 32.
Find Host Datastores
Click to show the available datastores for the selected hypervisor.
Host Datastore
Click the list to select the data store from the ones available on the host.
Find Host Networks
Click to show the available virtual switches/bridges for the selected hypervisor.
IxVM Card Management Network
Click to select the Card Management Network information.
IxVM Test Network
Click to select the test network information for both Linux and Bare metal sources.

Jobs Manager

Jobs Manager is a component of IxVM's Deployment Wizard and it shows a multi-level progress log and thermometers indicating relative progress as the virtual chassis are built or upgraded.

Jobs Manager is a Windows application that appears in the notification area. It gets started on the host on startup and is used for the following activities:

The Jobs Manager notification area contains the following icons as the status of the IxVM JobInstaller service or the status of the current job that is being processed:

Figure 39-53.

The Jobs Manager icons in the notification area

In addition to this, a notification balloon appears for the following most important operations that take place while using Jobs Manager:

The Continue, Retry, Abort, Remove, and Rebuild chassis commands are available or unavailable depending on the selected job's current status. For example, you can only rebuild the chassis if the jobs have finished without errors. The Show log command refers to the currently selected job and creates a .csv file that shows the message exchange that took place between IxVM's JobInstaller service and the computer that is upgraded or built.

The following image shows the current progress of jobs:

Figure 39-54.

The The Jobs Manager List Window

Troubleshooting and Tips

Following are some of the troubleshooting tips:

Tips

Active iptables firewall on host

IxServer and IxVM communicates through TCP or UDP ports, and if there is a firewall on the host computer, you need to add some additional rules to allow traffic from IxServer.

If the Linux VM communicates with the host through a bridge, the iptables firewall should not affect the communication between the Windows VM and Linux VM.

If the traffic between the Windows VM and Linux VM is blocked, following are some examples of how to add new rules so that IxVM works properly.

The examples show how to allow the traffic for the udp port 123, which is required for NTP.

iptables -A INPUT -p udp --dport 123 -j ACCEPT 
When there is no more need to run IxVM, you can delete 
this rule by typing the following iptables command:
iptables -D INPUT -p udp --dport 123 -j ACCEPT 

The iptables rules order is important because the first rule has precedence. If one iptable rule matches the incoming traffic, the rest of them are ignored. Hence, the iptable rule that accepts the traffic should be added before the iptable rule that drops or rejects the traffic.

For viewing the iptable filtering rules, use the following command:

iptables –nvL. 

The following output represents an example output of the iptables –nvL command:

Figure 39-57.

The example output of the iptables –nvL command

This output shows that there are two ports and protocols that are accepted by the iptable firewall and the last rule shows that everything else is rejected.

If you want to add another iptable rule to accept additional traffic, you need to add it before the REJECT rule.

The following command adds the rule to accept the NTP traffic before the reject rule.

iptables -I INPUT 1 -p udp --dport 123 -j ACCEPT 

The preceding command adds the iptable rule on the first position. You can specify the position of the iptable rule by modifying the parameter.

iptables -I INPUT x ... (x represents the rule number) 

To delete such a rule, the rule number must be specified:

iptables -D INPUT x (x-represents the rule number) 

You should add the same rules for all the required ports. All the ports that are needed for communication between Windows VM and Linux VM are listed in the `TCP/UDP Ports Required' section.

In addition, the firewall should allow the outgoing traffic from the Linux VMs. One way for doing this is to allow all the traffic that comes from the Linux VMs.

iptables -I OUTPUT 1 -p tcp --src a.b.c.d -j ACCEPT, 
where a.b.c.d is the Linux VM ip.  

Note that this ip should be internet-routable.

TclAPI Support

This section describes the IxOS TclAPI commands and statistics that you can use with an IxVM virtual load module.

In this section:

IxOS Tcl API Commands

IxOS Statistics

IxOS Tcl API Commands

You can use the following IxOS TclAPI commands with IxVM virtual load modules:

IxOS Statistics

You can use the following IxOS statistics IxVM virtual load modules:

Note: Some statistics may only work if the protocol or feature they measure is enabled. For example, bgpTotalSessions only returns a valid value if BGP is enabled. This is the same behavior as for physical load module.

List of DHCP Options

These are option names used in Open DHCP Server. These are based on IANA names less spaces and dashes. Please refer to http://www.iana.org/assignments/bootp-dhcp-parameters/bootp-dhcp-parameters.xml for more info. You can also use options not listed here using tag names directly.

Tag
Option Name in
Open DHCP Server
IANA Name
Meaning
1

SubnetMask

Subnet Mask

Subnet Mask Value

2

TimeOffset

Time Offset

Time Offset in Seconds from UTC (note: deprecated by 100 and 101)

3

Router

Router

N/4 Router addresses

4

TimeServer

Time Server

N/4 Timeserver addresses

5

NameServer

Name Server

N/4 IEN-116 Server addresses

6

DomainServer

Domain Server

N/4 DHCP Server addresses

7

LogServer

Log Server

N/4 Logging Server addresses

8

QuotesServer

Quotes Server

N/4 Quotes Server addresses

9

LPRServer

LPR Server

N/4 Printer Server addresses

10

ImpressServer

Impress Server

N/4 Impress Server addresses

11

RLPServer

RLP Server

N/4 RLP Server addresses

12

Hostname

Hostname

Hostname string

13

BootFileSize

Boot File Size

Size of boot file in 512 byte chunks

14

MeritDumpFile

Merit Dump File

Client to dump and name the file to dump it to

15

DomainName

Domain Name

The DNS domain name of the client

16

SwapServer

Swap Server

Swap Server address

17

RootPath

Root Path

Path name for root disk

18

ExtensionFile

Extension File

Path name for more BOOTP info

19

ForwardOn/Off

Forward On/Off

Enable/Disable IP Forwarding

20

SrcRteOn/Off

SrcRte On/Off

Enable/Disable Source Routing

21

PolicyFilter

Policy Filter

Routing Policy Filters

22

MaxDGAssembly

Max DG Assembly

Max Datagram Reassembly Size

23

DefaultIPTTL

Default IPTTL

Default IP Time to Live

24

MTUTimeout

MTU Timeout

Path MTU Aging Timeout

25

MTUPlateau

MTU Plateau

Path MTU Plateau Table

26

MTUInterface

MTU Interface

Interface MTU Size

27

MTUSubnet

MTU Subnet

All Subnets are Local

28

BroadcastAddress

Broadcast Address

Broadcast Address

29

MaskDiscovery

Mask Discovery

Perform Mask Discovery

30

MaskSupplier

Mask Supplier

Provide Mask to Others

31

RouterDiscovery

Router Discovery

Perform Router Discovery

32

RouterRequest

Router Request

Router Solicitation Address

33

StaticRoute

Static Route

Static Routing Table

34

Trailers

Trailers

Trailer Encapsulation

35

ARPTimeout

ARP Timeout

ARP Cache Timeout

36

Ethernet

Ethernet

Ethernet Encapsulation

37

DefaultTCPTTL

Default TCPTTL

Default TCP Time to Live

38
KeepaliveTime
Keepalive Time
TCP Keepalive Interval
39
KeepaliveData
Keepalive Data
TCP Keepalive Garbage
40
NISDomain
NIS Domain
NIS Domain Name
41
NISServers
NIS Servers
NIS Server Addresses
42
NTPServers
NTP Servers
NTP Server Addresses
44
NETBIOSNameSrv
NETBIOS Name Srv
NETBIOS Name Servers
45
NETBIOSDistSrv
NETBIOS Dist Srv
NETBIOS Datagram Distribution
46
NETBIOSNodeType
NETBIOS Node Type
NETBIOS Node Type
47
NETBIOSScope
NET BIOS Scope
NETBIOS Scope
48
XWindowFont
XWindow Font
X Window Font Server
49
XWindowManager
XWindow Manager
X Window Display Manager
51
AddressTime
Address Time
IP Address Lease Time
58
RenewalTime
Renewal Time
DHCP Renewal (T1) Time
59
RebindingTime
Rebinding Time
DHCP Rebinding (T2) Time
62
NetWare/IPDomain
NetWare/IP Domain
NetWare/IP Domain Name
63
NetWare/IPOption
NetWare/IP Option
NetWare/IP sub Options
64
NIS-Domain-Name
NIS-Domain-Name
NIS+ v3 Client Domain Name
65
NIS-Server-Addr
NIS-Server-Addr
NIS+ v3 Server Addresses
66
TFTPServerName
Server Name
TFTP Server Name
67
BootFileOption
BootFile-Option
Boot File Name
68
HomeAgentAddrs
Home-Agent-Addrs
Home Agent Addresses
69
SMTPServer
SMTP-Server
Simple Mail Server Addresses
70
POP3Server
POP3-Server
Post Office Server Addresses
71
NNTPServer
NNTP-Server
Network News Server Addresses
72
WWWServer
WWW-Server
WWW Server Addresses
73
FingerServer
Finger-Server
Finger Server Addresses
74
IRCServer
IRC-Server
Chat Server Addresses
75
StreetTalkServer
StreetTalk-Server
StreetTalk Server Addresses
76
STDAServer
STDA-Server
ST Directory Assist. Addresses
78
DirectoryAgent
Directory Agent
directory agent information
79
ServiceScope
Service Scope
service location agent scope
83
iSNS
iSNS
Internet Storage Name Service
85
NDSServers
NDS Servers
Novell Directory Services
86
NDSTreeName
NDS Tree Name
Novell Directory Services
87
NDSContext
NDS Context
Novell Directory Services
95
LDAP
LDAP
Lightweight Directory Access Protocol
100
PCode
PCode
IEEE 1003.1 TZ String
101
TCode
TCode
Reference to the TZ Database
112
NetinfoAddress
Netinfo Address
NetInfo Parent Server Address
113
NetinfoTag
Netinfo Tag
NetInfo Parent Server Tag
114
URL
URL
URL