PDF version of this section PDF version of entire manual

Get this 
section in PDF
Get entire 
manual in PDF

PreviousNextIndex


Chapter 7: XGS12 Chassis


This chapter provides details about the XGS12 chassis—its specifications and features.

The XGS12 Chassis is the next generation high performance platform capable of supporting all XM form factor load modules, including full chassis configurations of the Xcellon load modules. It is a 12-slot chassis with high-speed backplane (160 Gbps between each adjacent two cards) designed for aggregation across load modules.

XGS12 supports both IxLoad and BreakingPoint software applications. The chassis architecture supports easy setup and management of high scale, multi-user system. It has a pluggable system controller for chassis management. Additional applications and load modules will be supported in future software releases.

The following are the two chassis bundles:

The chassis provides improved modularity and access to the major components to reduce downtime of a failed chassis and to reduce the probability of needing to remove a failed chassis from the test environment.

The four XGS12-HS chassis modules that are bundled together are shown in Table 7-1.
Table 7-1. XGS12-HS Part Numbers and Modules
Part Number
Description
941-0041
Chassis Frame Assembly, with STD SYNC
942-0048
High Performance Processor Module
942-0031
Fan Assembly Module
942-0032
6000W Power Supply Module

The four XGS12-Standard chassis modules that are bundled together are shown in Table 7-2.
Table 7-2. XGS12-Standard Part Numbers and Modules
Part Number
Description
941-0041
Chassis Frame Assembly, with STD SYNC
942-0033
Standard Processor Module
942-0031
Fan Assembly Module
942-0032
6000W Power Supply Module

The XGS12 chassis, shown in Figure 7-1, allows the hot-swapping of load modules, without requiring the chassis to be powered down. The Processor module for the XGS12 chassis is not hot swappable.

The System Controller is plugged into the front of the chassis, slot 0. The power supplies and fans are accessible from the rear of the chassis. Each of the modular components is capable of being removed in the field and replaced with minimum downtime.

Figure 7-1.

XGS12 Chassis

The component modules of the XGS12 chassis are shown in the following figure:

Specifications

The XGS12 chassis specifications are contained in the following tables.

Table 7-3. XGS12-HS Processor Module Specifications
Processor Module
Field replaceable and removable processor card module with 2 x INTEL Sandy Bridge EP, E5-2658 2.1 GHz processors
Memory
64 GB RAM
Hard Disk Drive
Dual 400 GB Solid-State Drives
Operating System
Native Linux OS and Win7 VM for IxOS
Other Specs
IPMI support
Table 7-4. XGS12-Standard Processor Module Specifications
Processor Module
Field replaceable and removable processor card module with an Intel 2.26 GHz Core™ 2 Duo processor with 4 GB CPU memory, and 250 GB SATA hard drive
Memory
4GB
Hard Disk Drive
250GB
Operating System
Windows 7
 
Caution–Battery replacement
There is danger of explosion if battery is incorrectly replaced. Do not attempt to replace the battery.
Return to Ixia Customer Service for replacement with the same or equivalent type of battery. Ixia disposes of used batteries according to the battery manufacturer's instructions.
 
Note: The serial number for the Processor Module is located on module itself. This is used as the overall chassis serial number.
Table 7-5. XGS12 Chassis Specifications
Size
  • 19.0 in. W x 19.21 in. H x 27.2 in. D
  • 48.26cm W x 48.79cm H x 69.09cm D
  • 11 rackmount units (11RU)
Load Module Slots
12 (compatible with Ixia XM form factor load modules)
Chassis Power
The chassis requires three single phase, 200-240VAC, 50/60Hz circuits, each capable of providing 3680 watts. These circuits must provide protection against over-currents, short circuits and earth faults for the XGS12 chassis. A 20A circuit breaker for each circuit is also required.
All three power cords must be plugged into their single phase 200-240VAC, 50Hz/60Hz power sources at the same time for correct operation of the chassis.
Note: The chassis power supplies are interlocked with the rear cover which must be installed for them to be enabled. After removing or installing the rear panel, ensure thumbscrews have been tightened down with a 'Flat Blade' screwdriver.
Note: The load module power is enabled by the Ixia server program. If it is not running, the load modules will not be powered on.
Power Cords
All three power cords are required to operate the XGS12 chassis power supplies.
Power Cord shipments:
  • Ixia provides three power cords that are configured and rated to meet the specifications of the target country where the chassis is being installed.
  • For North American customers, the power cords have NEMA L6-20P plugs for attachment to the power source and IEC-60320-C19 connectors that attach to the XGS12 chassis.
  • For International shipments, the power cords supplied has plugs suitable for each destination country's power source and IEC-60320-C19 connectors that attach to the XGS12 chassis.
Chassis Weights
Frame:
  • 64 lbs. (29.1 kg) empty, component weight
  • 97 lbs. (44.1 kg) average shipping weight (with filler panels)
Fan module:
  • 10.2 lbs. (4.63 kg) component weight
  • 17.3 lbs. (7.86 kg) average shipping weight
Power Supply module:
  • 28 lbs. (12.72 kg) component weight
  • 35.1 lbs. (15.95 kg) average shipping weight
Processor module (Standard):
  • 2.7 lbs. (1.23 kg) component weight
  • 8.5 lbs. (3.86 kg) average shipping weight
Processor module (High Performance
  • 10 lbs. (4.54 kg) component weight
  • 15.8 lbs. (7.17 kg) average shipping weight
Warning: Total chassis weight, without any load modules installed is 112.2 lbs. (50.89 kg). Do not attempt to lift the fully assembled chassis.
Fan Module
Field replaceable chassis fan assembly that is easily installed and removed.
Air flow Clearance
12 inches is required at the rear of the chassis.
24 inches of clearance is preferred.
Power Supply Module
Field replaceable power supply module that is easily installed and removed.
There are three 2825W power supplies in the Power Supply Module.
Each power supply may be removed or replaced separately.
Timing Sources
Internal clock, synchronized with another Ixia chassis, GPS AFD-1unit, AFD2 IRIG-B unit or with the Timing Distribution Module.
Shipping Vibration
FED-STD-101C, Method 5019.1/5020.1
Operating temperature
41×F to 104×F, (5×C to 40×C)
Note: Some high-density/high performance load modules require a lower maximum ambient operating temperature than the standard for the chassis. When a load module that requires the lower maximum operating temperature is installed in an XM chassis, the maximum operating temperature of the chassis is adjusted downward to match the maximum operating temperature of the load module. The operating temperature range specification is specified in the published datasheet for these load modules.
Storage temperature
41oF to 122oF, (5oC to 50oC)
Operating Humidity
0% to 85%, non-condensing
Storage Humidity
0% to 85%, non-condensing
Noise
The XGS12 chassis running at maximum fan speed capacity may produce noise levels up to 87 dB(A). This is measured per the GR-63-CORE, Issue 1, paragraph 5.6.3 specification. The use of appropriate ear protection is recommended to protect against hearing impairment. Consult local health and safety regulations for recommended maximum exposure levels for noise and ear protection devices.
 
Shown below are the maximum XGS12 chassis sound levels measured according to GR-63-CORE, Issue 1, Paragraph 5.6.3.
  • Front: 83.5 dB(A)
  • Left Side: 84.2 dB(A)
  • Rear: 86.5 dB(A)
  • Right Side: 84.4 dB(A)

Hearing Protection: The XGS12 chassis generates noise levels above 80 dB(A). Ear protection must be worn. The use of appropriate ear protection is recommended to protect against hearing impairment. Consult local health and safety regulations for recommended maximum exposure levels for noise and ear protection devices.

Table 7-6. XGS12 Chassis controls and indicators
Front Panel Switches
On/Off momentary power push button
Monitor
HD-DB15 Super VGA
Ethernet
The Standard XGS12 chassis has two RJ-45 10/100/1000Mbps Gigabit Ethernet Management Port.
The High Performance XGS12 chassis has one RJ-45 1GBaseT/10GBaseT management port, one RJ-45 RS232 serial port.
USB
The Standard XGS12 chassis has 4 USB dual type A, 4-pin jack connectors.
The High Performance XGS12 chassis has two USB ports. Additionally there are four SFP+ sockets and one RJ-45 1GBaseT/10GBaseT port that are for future use.
Sync In
Single Sync In jack with a 4-pin RJ11
Sync Out
Single Sync Out jack with a 4-pin RJ11
Front Panel Indicators
 
2 Paired LEDs above each slot position indicating Power and Active status.
 
2x16 LCD on front panel indicating chassis information.

Figure 7-2. Safety Features

XGS12 Chassis Installation Precautions

XGS12 chassis installation precautions are as follows:

LEDs/LCD Display

The XGS12 chassis has front panel LEDs for each load module slot.
Table 7-7. XGS12 LEDs
Label
Color
Description
Power
Green
When the Power LED is flashing, the board is being detected or initialized.
The Power LED is illuminated when the board is powered.
In Use
Green
The Active LED is illuminated when a user has taken ownership of the load module.

LCD Display

An LCD display is provided on the chassis to indicate the status of the chassis without an external display device (monitor). The LCD operates in two modes:

CPU Slot LED Definitions

The specifications of LEDs for the Processor module and the LEDs above the Processor module slot are shown in the following table:

ESD Discharge Warning: Operator intervention may be required to power cycle the unit or restart a software program in the event the unit is upset by electrostatic discharge.

Table 7-8. LED Specifications
 
LED
Color
Description
On the chassis front face
CPU card Slot LED
Yellow
The backplane is initializing.
 
 
Green
The backplane has initialized
Processor module - front panel
Stdby Pwr LED
 
Green
5V Stand-by power is available
 
CPU Pwr LED
Green
CPU Card power is available
 
HDD Act LED
 
 
 
Bkpln Link LED
Green
PCIe link to backplane is up
Processor module - Ethernet LEDs for each port
Link LED
Green
Port has link
Note: Link and Activity LEDs are included for all Ethernet ports.
 
Act LED
 
Flashes when port has activity

Supported Modules

The modules that are supported on the XGS12 are listed in the following table.
Table 7-9. Supported Modules
Part Number
Module
Function
944-1200
PerfectStorm 10GE 8-port Fusion (PS10GE8NG)
PerfectStorm 10GE Fusion 8-port Load Module, 10GE 8-port SFP+ with support for IxLoad and BreakingPoint software.
Compatible ONLY with XGS12-HS, 12-SLOT CHASSIS BUNDLE with XGS12 rack mountable chassis and High Performance Controller Module (940-0006).
944-1201
PerfectStorm 40GE 2-port Fusion (PS40GE2NG)
PerfectStorm 40GE Fusion 2-port Load Module, 40GE 2-port QSFP+ with support for IxLoad and BreakingPoint software.
Compatible ONLY with XGS12-HS, 12-SLOT CHASSIS BUNDLE with XGS12 rack mountable chassis and High Performance Controller Module (940-0006).
944-1204
PerfectStorm 10GE 8-port (PS10GE8)
PerfectStorm 10GE 8-port Load Module, 10GE 8-port SFP+ with support for only IxLoad software.
Compatible with XGS12-HS, 12-SLOT CHASSIS BUNDLE with XGS12 rack mountable chassis and High Performance Controller Module (940-0006) and XGS12, 12-SLOT CHASSIS BUNDLE with XGS12 rack mountable chassis and Standard Performance Controller Module (940-0007).
944-1205
PerfectStorm 40GE 2-port (PS40GE2)
PerfectStorm 40GE 2-port Load Module, 40GE 2-port QSFP+ with support for only IxLoad software.
Compatible with XGS12-HS, 12-SLOT CHASSIS BUNDLE with XGS12 rack mountable chassis and High Performance Controller Module (940-0006) and XGS12, 12-SLOT CHASSIS BUNDLE with XGS12 rack mountable chassis and Standard Performance Controller Module (940-0007).

Hot-Swap Procedure

Each XGS12 chassis provides the ability of removing and reinstalling a load module without requiring the removal of power from the rest of the chassis. The process of removing/installing a Load Module does not impact either the operation of the OS or remaining load modules installed in the chassis.

The hot-swap procedure is detailed in Appendix D Hot-Swap Procedure.

Cooling Fan Speed Control

The XGS12 chassis automatically monitors and measures the temperature of installed load modules. The XGS12 automatically adjusts the fan speed to maintain proper cooling.

Power outage recovery and Automatic booting scenario

The BIOS on the XGS12 is set to Power On after a power failure.

The XGS12 chassis will start up, boot Windows 7 and automatically login to the Ixia user account. Anything that is in the Startup folder will also launch..

Rack Mount Cautions

Caution: If this unit is installed in a network equipment rack, please observe the following precautions.

    1. Elevated Operating Ambient Temperature: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consider installing the equipment in an environment that is compatible with the maximum allowable ambient temperature specified for the chassis (40° C).
    2. Reduced Air Flow: Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not reduced. Do not block the back or the front of the chassis, and leave approximately 12 inches of space, 24 inches preferred, for the back of the unit for proper ventilation. The air flow clearance should be 12 inches on the front.
    3. Mechanical Loading: Mount the chassis so that it is level in the rack and that a hazardous condition is not caused. Please install all six mounting bolts.
    4. Circuit Overloading: Consider the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Pay attention to equipment nameplate ratings when addressing this concern.
    5. Reliable Earthing: Maintain reliable earthing (grounding) of rack-mounted equipment. Chassis frame should be screwed down to racks to ensure proper grounding path. In addition, pay special attention to supply connections other than direct connections to the branch circuit (such as use of power strips).
    6. Replacement of the power supply cord must of the same type cord and plug configuration that was shipped with the unit.

PreviousNextIndex

Did this document 
answer your question?

If not, let us know!


Voice: (818) 871-1800
Fax: (818) 871-1805
info@ixiacom.com